# Antibiotic Dilution / MIC Reference Calculator (education)

The current ledger marks this instrument verified clean within the source-bound verification corpus.

Status: **VERIFIED_CLEAN**Lifecycle: **verified-clean**

## Inspectable records

[01**Overview**Purpose and lifecycle](<https://guthlabs.ai/docs/instruments/antibiotic-dilution-mic-reference-calculator-education/>)[02**Mechanism**Method and assumptions](<https://guthlabs.ai/docs/instruments/antibiotic-dilution-mic-reference-calculator-education/mechanism/>)[03**Implementation**Binding and validation](<https://guthlabs.ai/docs/instruments/antibiotic-dilution-mic-reference-calculator-education/implementation/>)[04**Qualification**Evidence and errata](<https://guthlabs.ai/docs/instruments/antibiotic-dilution-mic-reference-calculator-education/qualification/>)

## Ledger state

The current ledger marks this instrument verified clean within the source-bound verification corpus.

**Area**: Biology, Medicine & Pharmacology (educational estimates only — every panel labeled not-medical-advice)

**Tranche**: tranche-5

**Evidence ID**: t5-187

**Ledger rows**: 1

No ledger note is attached.

## Review findings

The mathematical formula is correct under the stated 2-fold serial-dilution assumptions. NEEDS_REVIEW is required because the C0-versus-C1 output convention and the physical 1:2 dilution procedure are unspecified. The existing educational, lab-planning, protocol-verification, and not-a-treatment-tool labeling is appropriate.

### Formula and scope findings

- C_n=C0/2^n is the standard formula for a serial 2-fold dilution only when every step produces a 1:2 dilution, such as equal volumes of sample and diluent; that operational constraint is not stated.

- The spec does not define whether the output series includes the undiluted stock C0 or only diluted wells/tubes C1 through Cn.

- This computes nominal concentrations for MIC-test setup but does not determine an MIC endpoint; the output claim should not imply that it performs MIC interpretation.

### Unit assumptions

- C0 and every Cn use the same concentration unit unless an explicit conversion is requested.

- The dilution factor 2 is dimensionless; each step halves the concentration.

- For the unit-conversion test, 1 mg/mL = 1000 µg/mL.

- number of dilution steps must be a finite, nonnegative integer; the test vectors define outputs as C0 through Cn.

## Boundary hardening

**BREAK_CLAIMED** · SELF_FLAGGED

At 1075 dilution steps with stock concentration 1, the mathematical result is approximately 2.4703282292062327e-324, but plain JavaScript arithmetic underflows it to 0. The specification also leaves integer-step validation and series indexing/unit conventions implicit.

## Errata and corrections

No applied erratum is attached to this unique-name record.

## Inspectable example

4 review vectors are recorded. One source-bound sample is shown below.

````
{
  "inputs": {
    "stock_concentration": 64,
    "concentration_unit": "µg/mL",
    "dilution_steps": 5,
    "output_convention": "C0 through Cn"
  },
  "expected_outputs": {
    "concentrations_ug_per_mL": [
      64,
      32,
      16,
      8,
      4,
      2
    ]
  },
  "working": "C0 = 64 µg/mL; C1 = 64/2 = 32 µg/mL; C2 = 32/2 = 16 µg/mL; C3 = 16/2 = 8 µg/mL; C4 = 8/2 = 4 µg/mL; C5 = 4/2 = 2 µg/mL."
}
````