Guth
NewsContactDocs
Page actions
View as Markdown ↗
Explore MCP tools ↗

instrument / verified-clean

Brayton Cycle Efficiency Calculator

The current ledger marks this instrument verified clean within the source-bound verification corpus.

Status: Verified in ledgerLifecycle: verified-clean

Inspectable records

Ledger state

The current ledger marks this instrument verified clean within the source-bound verification corpus.

Area
Thermodynamics, Fluids & Aero
Tranche
tranche-4
Evidence ID
t4-024
Ledger rows
1

No ledger note is attached.

Review findings

The base simple-cycle efficiency formula is standard, but the specification is incomplete for its claimed outputs and does not define the regenerative efficiency adjustment. Verdict remains needs review until the missing work equations, regeneration model, temperature units, input constraints, and zero-denominator behavior are explicitly specified.

Formula and scope findings

  • The base formula η=1−1/rp^((γ−1)/γ) is correct only for an ideal simple Brayton cycle with constant γ, isentropic compression and expansion, and no pressure losses.
  • No formula is provided for compressor-exit temperature, turbine-exit temperature, compressor work, turbine work, net specific work, or back-work ratio, even though those outputs are claimed.
  • The regenerative adjustment is unspecified: effectiveness ε alone does not define η without the regenerator temperature relations and heat-input definition.
  • A standard regeneration model must specify T2r=T2+ε(T4−T2), T4r=T4−ε(T4−T2), and η=(wt−wc)/qin, with qin=Cp(T3−T2r).
  • Regeneration is physically useful only when T4>T2; otherwise the regenerator should be bypassed or ε should be treated as zero.
  • The listed formula does not use turbine/compressor inlet temperatures or Cp, so it cannot by itself produce specific work or back-work ratio.

Unit assumptions

  • Temperatures are absolute temperatures in kelvin for all thermodynamic formulas; Celsius or Fahrenheit values must be converted before multiplication or division.
  • Pressure ratio rp is dimensionless and means compressor outlet absolute pressure divided by compressor inlet absolute pressure.
  • γ is dimensionless and assumed constant, with γ>1; the examples use γ=1.4 for air.
  • Cp is assumed constant and expressed in kJ/(kg·K); the examples use Cp=1.005 kJ/(kg·K), so work outputs are in kJ/kg.
  • The test vectors use the standard ideal-cycle relations T2=T1·rp^((γ−1)/γ), T4=T3/rp^((γ−1)/γ), wc=Cp(T2−T1), wt=Cp(T3−T4), and wnet=wt−wc.
  • For regenerated cases, the standard no-pressure-loss regenerator model and ε between 0 and 1 are assumed.

Boundary hardening

Recorded hazards

  • Division by zero occurs for back-work ratio when turbine work is zero, including the rp=1 boundary case.
  • The exponent requires γ>1; γ=1 causes a degenerate zero-efficiency result, and γ≤1 is not a valid ordinary ideal-gas Brayton-cycle input.
  • rp must be positive; rp=0 is invalid and negative pressure ratios are nonphysical.
  • Regenerator effectiveness should be constrained to 0≤ε≤1.
  • The regenerator formula requires a specified operating condition such as T4>T2; applying regeneration when T4≤T2 can produce nonphysical heat flow or misleading efficiency.
  • If T3≤T2, the heat-addition denominator is zero or negative and efficiency is undefined or nonphysical.
  • Celsius inputs used directly instead of kelvin produce incorrect temperatures and work values.
  • Cp must be supplied or given a clearly documented default; changing Cp changes specific work but not the ideal simple-cycle efficiency.

Errata and corrections

No applied erratum is attached to this unique-name record.

Inspectable example

4 review vectors are recorded. One source-bound sample is shown below.

{
  "inputs": {
    "rp": 4,
    "gamma": 1.4,
    "T1_K": 288,
    "T3_K": 1400,
    "Cp_kJ_per_kgK": 1.005,
    "regeneration": false
  },
  "expected_outputs": {
    "eta": 0.32705,
    "specific_work_kJ_per_kg": 319.497,
    "back_work_ratio": 0.30569
  },
  "working": "a=(γ−1)/γ=0.4/1.4=2/7. F=rp^a=4^(2/7)=1.485994. T2=T1·F=288·1.485994=427.966 K. T4=T3/F=1400/1.485994=942.130 K. wc=Cp(T2−T1)=1.005·(427.966−288)=1.005·139.966=140.666 kJ/kg. wt=Cp(T3−T4)=1.005·(1400−942.130)=1.005·457.870=460.163 kJ/kg. wnet=wt−wc=460.163−140.666=319.497 kJ/kg. η=1−1/F=1−1/1.485994=0.32705. Back-work ratio=wc/wt=140.666/460.163=0.30569."
}

Related workflows

Sources and evidence

These pointers bind the page to evidence. They do not grant authority or collapse verification into deployment.

  • VERIFIED_LEDGER.json · VERIFIED_CLEAN
  • evidence-tranche4/tranche4-results.json