Source: https://guthlabs.ai/docs/instruments/cable-catenary-sag-tension-calculator/

instrument / verified-with-binding-errata

# Cable/Catenary Sag-Tension Calculator

The current ledger marks this instrument verified with errata that must be applied at binding time.

Status: **VERIFIED_WITH_ERRATA**Lifecycle: **verified-with-binding-errata**

## Inspectable records

[01**Overview**Purpose and lifecycle](<https://guthlabs.ai/docs/instruments/cable-catenary-sag-tension-calculator/>)[02**Mechanism**Method and assumptions](<https://guthlabs.ai/docs/instruments/cable-catenary-sag-tension-calculator/mechanism/>)[03**Implementation**Binding and validation](<https://guthlabs.ai/docs/instruments/cable-catenary-sag-tension-calculator/implementation/>)[04**Qualification**Evidence and errata](<https://guthlabs.ai/docs/instruments/cable-catenary-sag-tension-calculator/qualification/>)

## Ledger state

The current ledger marks this instrument verified with errata that must be applied at binding time.

**Area**: Mechanical, Civil & Structural Engineering — Statics/Dynamics, Strength of Materials, Machine Design, Civil, HVAC, Vibration

**Tranche**: tranche-6

**Evidence ID**: t6-140

**Ledger rows**: 1

No ledger note is attached.

## Review findings

The uniform-load parabolic formulas are mathematically sound under the stated assumptions, and the exact catenary test uses a fully specified symmetric equal-support interpretation. However, the specification omits the cable-length formula, exact-catenary parameter relations and convergence details, and claims point-load capability without providing a point-load algorithm. These ambiguities require review before catalog approval.

### Formula and scope findings

- The parabolic formulas for horizontal tension and maximum tension are standard for a level-span cable with uniform load w per unit horizontal span, but that load convention is not stated.

- The cable-length formula is missing. Under the parabolic approximation, the standard length is S=(L/2)sqrt(1+(4d/L)^2)+(L^2/(8d))asinh(4d/L).

- The exact catenary equation y=a·cosh(x/a) requires a vertical datum and horizontal origin; for a symmetric cable with its lowest point at x=0, the sag-referenced equation is y=a[cosh(x/a)-1].

- Exact catenary mode must define the relation used to solve a: d=a[cosh(L/(2a))-1], assuming equal-level supports and uniform load per unit horizontal length. It must also define T_h=w·a, T_max=w·a·cosh(L/(2a)), and S=2a·sinh(L/(2a)).

- Point loads are claimed in the description, but no point-load statics equations, load locations, or piecewise cable geometry are specified. The listed uniform-load parabolic and catenary formulas do not handle arbitrary point loads.

- The parabolic approximation becomes inaccurate for large d/L; no numerical validity threshold is specified despite the honest label referring to small sag-to-span ratio.

### Unit assumptions

- L and d use the same length unit.

- w is force per unit horizontal span, such as kN/m or N/m; it is not force per unit cable length.

- T_h and T_max have the same force unit as w multiplied by the length unit.

- For the exact catenary vectors, the cable is symmetric, supports are at equal elevation, and the lowest point is at midspan.

- Inverse hyperbolic sine is dimensionless and is evaluated as asinh(x)=ln(x+sqrt(1+x^2)).

## Boundary hardening

**BREAK_CLAIMED** · SELF_FLAGGED

The calculator breaks on zero span because T_max and cable length become undefined through division by zero; it also has a physical-convention hazard when a signed negative load is supplied and the interface does not specify whether load means signed force or nonnegative magnitude.

## Errata and corrections

### Tranche errata

**cable_length_m** · vector 2

94.542454

29.578857

10× slip inside her own Correction: writes 5*1.443635475=72.1817738 (true 7.218); a 20 m span with 10 m sag cannot be 94.5 m of cable

## Inspectable example

4 review vectors are recorded. One source-bound sample is shown below.

````
{
  "inputs": {
    "mode": "parabolic",
    "L_m": 100,
    "sag_d_m": 5,
    "load_w_kN_per_m": 1
  },
  "expected_outputs": {
    "T_horizontal_kN": 250,
    "T_max_kN": 254.950976,
    "cable_length_m": 100.662723
  },
  "working": "T_h=wL^2/(8d)=1·100^2/(8·5)=10000/40=250 kN. 4d/L=20/100=0.2. T_max=T_h·sqrt(1+(4d/L)^2)=250·sqrt(1+0.2^2)=250·sqrt(1.04)=250·1.019803903=254.950976 kN. Using the standard parabolic arc-length formula, S=(L/2)sqrt(1+(4d/L)^2)+(L^2/(8d))asinh(4d/L)=50·1.019803903+250·asinh(0.2)=50.9901952+250·0.198690110=100.662723 m."
}
````

## Related workflows

No source-defined multi-instrument workflow membership is recorded.

## Sources and evidence

These pointers bind the page to evidence. They do not grant authority or collapse verification into deployment.

- `VERIFIED_LEDGER.json · VERIFIED_WITH_ERRATA`

- `evidence-tranche6/tranche6-results.json`

- `BOUNDARY_HAZARD_CATALOG.json`