eGFR (MDRD, legacy)

The current ledger marks this instrument verified clean within the source-bound verification corpus.

Status: VERIFIED_CLEANLifecycle: verified-clean

Inspectable records

Ledger state

The current ledger marks this instrument verified clean within the source-bound verification corpus.

Area
Biology, Medicine & Pharmacology (educational estimates only — every panel labeled not-medical-advice)
Tranche
tranche-4
Evidence ID
t4-026
Ledger rows
1

No ledger note is attached.

Review findings

Educational estimate only and not medical advice, consistent with the supplied honest label. The catalog must explicitly identify whether this is the race-free IDMS-traceable MDRD variant with coefficient 175, rather than another historical MDRD variant.

Formula and scope findings

  • The formula is correct for the IDMS-traceable 4-variable MDRD equation without a race coefficient: 175×SCr^-1.154×Age^-0.203×(0.742 if female). However, 'MDRD, legacy' is ambiguous because historical MDRD variants commonly used a 186 coefficient and, in older implementations, an additional Black race coefficient; the intended variant must be named explicitly.
  • The input 'sex' is underspecified: the formula defines a female multiplier, but behavior for unknown, nonbinary, or missing values is not stated.

Unit assumptions

  • Age is in completed years and serum creatinine is in mg/dL.
  • The output is normalized to a body-surface area of 1.73 m² and is reported in mL/min/1.73 m².
  • If serum creatinine is supplied in µmol/L, convert using SCr_mg/dL = SCr_µmol/L ÷ 88.4 before applying the formula.
  • The 0.742 multiplier applies only when the selected formula convention classifies the patient as female; otherwise the multiplier is 1.

Boundary hardening

BREAK_CLAIMED · SELF_FLAGGED

The formula has undefined or non-physiologic boundary inputs that require validation: age = 0 produces an infinite mathematical result, negative serum creatinine produces an undefined real power, and an unspecified creatinine unit can produce an orders-of-magnitude error.

Errata and corrections

No applied erratum is attached to this unique-name record.

Inspectable example

4 review vectors are recorded. One source-bound sample is shown below.

{
  "inputs": {
    "age_years": 60,
    "sex": "male",
    "serum_creatinine_mg_dL": 1
  },
  "expected_outputs": {
    "eGFR_mL_min_1_73m2": 76.22
  },
  "working": "SCr^-1.154 = 1.0^-1.154 = 1.000. Age^-0.203 = 60^-0.203 ≈ 0.43555. Male multiplier = 1.000. eGFR = 175 × 1.000 × 0.43555 × 1.000 = 76.22 mL/min/1.73 m²."
}