instrument / verified-clean

Hydration Needs Estimator

The current ledger marks this instrument verified clean within the source-bound verification corpus.

Status: VERIFIED_CLEANLifecycle: verified-clean

Inspectable records

Ledger state

The current ledger marks this instrument verified clean within the source-bound verification corpus.

Area
Everyday & Life
Tranche
tranche-4
Evidence ID
t4-247
Ledger rows
1

No ledger note is attached.

Review findings

The arithmetic is valid under the stated assumptions, but the specification is not implementation-deterministic because activity-rate selection and climate_add are undefined. Define the climate algorithm, exercise-intensity mapping, input bounds, and ounce convention before release.

Formula and scope findings

  • The activity adjustment is specified only as a broad range of 500-1000 ml/hr; the formula does not define how exercise intensity selects a rate within that range.
  • The formula does not explicitly state that activity_add equals exercise_duration_hours multiplied by an activity rate in ml/hr.
  • climate_add is undefined: there is no temperature threshold, climate category, or numeric adjustment.
  • The 35 ml/kg/day baseline is a general rule of thumb, not a universally valid hydration requirement; it should not be presented as an individualized or clinically validated target.
  • Adding a fixed exercise amount to the baseline may not account for individual sweat rate, exercise conditions, or fluid intake from food and other beverages.

Unit assumptions

  • body weight is entered in kilograms.
  • The baseline result is milliliters per day: weight_kg × 35 ml/kg/day.
  • Exercise duration is measured in hours.
  • activity_add is interpreted as exercise_duration_hours × activity_rate_ml_per_hr.
  • The activity rate is assumed to be between 500 and 1000 ml/hr, inclusive.
  • climate_add is interpreted as an explicitly supplied number of milliliters per day; its calculation is not defined by the specification.

Boundary hardening

BREAK_CLAIMED · SELF_FLAGGED

The specification has no explicit validation for zero or non-finite inputs, can produce Infinity for extreme magnitudes, does not define the activity-intensity branch within the 500-1000 ml/hr range, and leaves weight units and climate_add calculation ambiguous.

Errata and corrections

No applied erratum is attached to this unique-name record.

Inspectable example

4 review vectors are recorded. One source-bound sample is shown below.

{
  "inputs": {
    "weight_kg": 70,
    "activity_duration_hr": 1,
    "activity_rate_ml_per_hr": 750,
    "climate_add_ml": 500
  },
  "expected_outputs": {
    "baseline_ml": 2450,
    "activity_add_ml": 750,
    "total_ml": 3700,
    "total_us_fl_oz": 125.11
  },
  "working": "baseline = 70 × 35 = 2450 ml/day; activity_add = 1 × 750 = 750 ml; total = 2450 + 750 + 500 = 3700 ml/day; US fl oz = 3700 ÷ 29.5735 = 125.112..., rounded to 125.11 fl oz."
}

Related workflows

Sources and evidence

These pointers bind the page to evidence. They do not grant authority or collapse verification into deployment.

  • VERIFIED_LEDGER.json · VERIFIED_CLEAN
  • evidence-tranche4/tranche4-results.json
  • BOUNDARY_HAZARD_CATALOG.json