Page actions
instrument / verified-clean
Hydration Needs Estimator
The current ledger marks this instrument verified clean within the source-bound verification corpus.
Inspectable records
Ledger state
The current ledger marks this instrument verified clean within the source-bound verification corpus.
- Area
- Everyday & Life
- Tranche
- tranche-4
- Evidence ID
- t4-247
- Ledger rows
- 1
No ledger note is attached.
Review findings
The arithmetic is valid under the stated assumptions, but the specification is not implementation-deterministic because activity-rate selection and climate_add are undefined. Define the climate algorithm, exercise-intensity mapping, input bounds, and ounce convention before release.
Formula and scope findings
- The activity adjustment is specified only as a broad range of 500-1000 ml/hr; the formula does not define how exercise intensity selects a rate within that range.
- The formula does not explicitly state that activity_add equals exercise_duration_hours multiplied by an activity rate in ml/hr.
- climate_add is undefined: there is no temperature threshold, climate category, or numeric adjustment.
- The 35 ml/kg/day baseline is a general rule of thumb, not a universally valid hydration requirement; it should not be presented as an individualized or clinically validated target.
- Adding a fixed exercise amount to the baseline may not account for individual sweat rate, exercise conditions, or fluid intake from food and other beverages.
Unit assumptions
- body weight is entered in kilograms.
- The baseline result is milliliters per day: weight_kg × 35 ml/kg/day.
- Exercise duration is measured in hours.
- activity_add is interpreted as exercise_duration_hours × activity_rate_ml_per_hr.
- The activity rate is assumed to be between 500 and 1000 ml/hr, inclusive.
- climate_add is interpreted as an explicitly supplied number of milliliters per day; its calculation is not defined by the specification.
Boundary hardening
BREAK_CLAIMED · SELF_FLAGGED
The specification has no explicit validation for zero or non-finite inputs, can produce Infinity for extreme magnitudes, does not define the activity-intensity branch within the 500-1000 ml/hr range, and leaves weight units and climate_add calculation ambiguous.
Errata and corrections
No applied erratum is attached to this unique-name record.
Inspectable example
4 review vectors are recorded. One source-bound sample is shown below.
{
"inputs": {
"weight_kg": 70,
"activity_duration_hr": 1,
"activity_rate_ml_per_hr": 750,
"climate_add_ml": 500
},
"expected_outputs": {
"baseline_ml": 2450,
"activity_add_ml": 750,
"total_ml": 3700,
"total_us_fl_oz": 125.11
},
"working": "baseline = 70 × 35 = 2450 ml/day; activity_add = 1 × 750 = 750 ml; total = 2450 + 750 + 500 = 3700 ml/day; US fl oz = 3700 ÷ 29.5735 = 125.112..., rounded to 125.11 fl oz."
}Related workflows
Sources and evidence
These pointers bind the page to evidence. They do not grant authority or collapse verification into deployment.