Page actions
instrument / verified-clean
Integrated Rate Law Solver
The current ledger marks this instrument verified clean within the source-bound verification corpus.
Inspectable records
Ledger state
The current ledger marks this instrument verified clean within the source-bound verification corpus.
- Area
- Chemistry & Materials
- Tranche
- tranche-6
- Evidence ID
- t6-119
- Ledger rows
- 1
No ledger note is attached.
Review findings
The three displayed integrated rate laws are standard and mathematically correct under their assumptions. Verdict is needs review because the specification does not define inverse-solving formulas, admissible domains, exact unit handling, or deterministic plotting bounds, and it does not explicitly label the model as an irreversible constant-condition single-reactant approximation.
Formula and scope findings
- The listed integrated laws are correct for irreversible, single-reactant reactions with constant volume and constant temperature, but the solver must explicitly provide the inverse forms for the claimed 'solve for any one' capability: zero-order t=([A]0-[A])/k, first-order [A]=[A]0 exp(-kt) and t=ln([A]0/[A])/k, and second-order t=(1/[A]-1/[A]0)/k.
- The specification does not state the required physical-domain constraints: [A]0>0, [A]>=0, t>=0, and k>0 for a consuming reaction. Zero-order calculations become physically invalid when t>[A]0/k; first- and second-order target concentrations must satisfy 0<[A]<=[A]0.
- The phrase 'solve for any one' is ambiguous because the declared inputs include order, k, [A]0, and t but do not identify whether [A], k, [A]0, or t may be the missing variable, nor how the solver represents a target concentration.
- The plotting output is underspecified: no time range, sampling resolution, or handling of the physically invalid negative-concentration portion of a zero-order curve is defined.
Unit assumptions
- Concentration [A] and [A]0 use the same concentration unit, such as mol/L (M).
- Time t and the rate constant k must use compatible units.
- For zero order, k has concentration/time units, such as M/s.
- For first order, k has inverse-time units, such as s^-1 or min^-1.
- For second order, k has concentration^-1 time^-1 units, such as M^-1 min^-1.
- The formulas assume an irreversible reaction involving one tracked reactant concentration, constant volume, constant temperature, and a constant rate constant.
Boundary hardening
Known limit · flagged by the author
The zero-concentration second-order request causes division by zero and must not produce an ordinary numeric time. Negative-k handling is also underspecified: literal arithmetic gives growth, while the conventional rate-constant interpretation should reject the input.
Errata and corrections
No applied erratum is attached to this unique-name record.
Inspectable example
4 review vectors are recorded. One source-bound sample is shown below.
{
"inputs": {
"order": 0,
"k": 0.0025,
"k_units": "M/s",
"A0": 0.1,
"A0_units": "M",
"t": 20,
"t_units": "s",
"solve_for": "A"
},
"expected_outputs": {
"A": 0.05,
"A_units": "M",
"sampled_points": [
{
"t": 0,
"A": 0.1
},
{
"t": 20,
"A": 0.05
},
{
"t": 40,
"A": 0
}
],
"curve_features": {
"slope": "-0.0025 M/s",
"zero_concentration_time": 40,
"zero_concentration_time_units": "s",
"valid_nonnegative_domain": "0 <= t <= 40 s"
}
},
"working": "Zero-order law: A=A0-kt. At t=20 s, kt=(0.0025 M/s)(20 s)=0.0500 M. Therefore A=0.100 M-0.0500 M=0.0500 M. Boundary check: at t=A0/k=(0.100 M)/(0.0025 M/s)=40.0 s, A=0; for t>40.0 s the algebraic result is negative and is not a physical concentration."
}Related workflows
No source-defined multi-instrument workflow membership is recorded.
Sources and evidence
These pointers bind the page to evidence. They do not grant authority or collapse verification into deployment.
VERIFIED_LEDGER.json · VERIFIED_CLEANevidence-tranche6/tranche6-results.jsonBOUNDARY_HAZARD_CATALOG.json