Guth
NewsContactDocs
Page actions
View as Markdown ↗
Explore MCP tools ↗

instrument / verified-clean

Integrated Rate Law Solver

The current ledger marks this instrument verified clean within the source-bound verification corpus.

Status: Verified in ledgerLifecycle: verified-clean

Inspectable records

Ledger state

The current ledger marks this instrument verified clean within the source-bound verification corpus.

Area
Chemistry & Materials
Tranche
tranche-6
Evidence ID
t6-119
Ledger rows
1

No ledger note is attached.

Review findings

The three displayed integrated rate laws are standard and mathematically correct under their assumptions. Verdict is needs review because the specification does not define inverse-solving formulas, admissible domains, exact unit handling, or deterministic plotting bounds, and it does not explicitly label the model as an irreversible constant-condition single-reactant approximation.

Formula and scope findings

  • The listed integrated laws are correct for irreversible, single-reactant reactions with constant volume and constant temperature, but the solver must explicitly provide the inverse forms for the claimed 'solve for any one' capability: zero-order t=([A]0-[A])/k, first-order [A]=[A]0 exp(-kt) and t=ln([A]0/[A])/k, and second-order t=(1/[A]-1/[A]0)/k.
  • The specification does not state the required physical-domain constraints: [A]0>0, [A]>=0, t>=0, and k>0 for a consuming reaction. Zero-order calculations become physically invalid when t>[A]0/k; first- and second-order target concentrations must satisfy 0<[A]<=[A]0.
  • The phrase 'solve for any one' is ambiguous because the declared inputs include order, k, [A]0, and t but do not identify whether [A], k, [A]0, or t may be the missing variable, nor how the solver represents a target concentration.
  • The plotting output is underspecified: no time range, sampling resolution, or handling of the physically invalid negative-concentration portion of a zero-order curve is defined.

Unit assumptions

  • Concentration [A] and [A]0 use the same concentration unit, such as mol/L (M).
  • Time t and the rate constant k must use compatible units.
  • For zero order, k has concentration/time units, such as M/s.
  • For first order, k has inverse-time units, such as s^-1 or min^-1.
  • For second order, k has concentration^-1 time^-1 units, such as M^-1 min^-1.
  • The formulas assume an irreversible reaction involving one tracked reactant concentration, constant volume, constant temperature, and a constant rate constant.

Boundary hardening

Known limit · flagged by the author

The zero-concentration second-order request causes division by zero and must not produce an ordinary numeric time. Negative-k handling is also underspecified: literal arithmetic gives growth, while the conventional rate-constant interpretation should reject the input.

Errata and corrections

No applied erratum is attached to this unique-name record.

Inspectable example

4 review vectors are recorded. One source-bound sample is shown below.

{
  "inputs": {
    "order": 0,
    "k": 0.0025,
    "k_units": "M/s",
    "A0": 0.1,
    "A0_units": "M",
    "t": 20,
    "t_units": "s",
    "solve_for": "A"
  },
  "expected_outputs": {
    "A": 0.05,
    "A_units": "M",
    "sampled_points": [
      {
        "t": 0,
        "A": 0.1
      },
      {
        "t": 20,
        "A": 0.05
      },
      {
        "t": 40,
        "A": 0
      }
    ],
    "curve_features": {
      "slope": "-0.0025 M/s",
      "zero_concentration_time": 40,
      "zero_concentration_time_units": "s",
      "valid_nonnegative_domain": "0 <= t <= 40 s"
    }
  },
  "working": "Zero-order law: A=A0-kt. At t=20 s, kt=(0.0025 M/s)(20 s)=0.0500 M. Therefore A=0.100 M-0.0500 M=0.0500 M. Boundary check: at t=A0/k=(0.100 M)/(0.0025 M/s)=40.0 s, A=0; for t>40.0 s the algebraic result is negative and is not a physical concentration."
}

Related workflows

No source-defined multi-instrument workflow membership is recorded.

Sources and evidence

These pointers bind the page to evidence. They do not grant authority or collapse verification into deployment.

  • VERIFIED_LEDGER.json · VERIFIED_CLEAN
  • evidence-tranche6/tranche6-results.json
  • BOUNDARY_HAZARD_CATALOG.json