Guth
NewsDocs
Page actions
View as Markdown ↗
Explore MCP tools ↗

instrument / verified-clean

Normality / Equivalents Calculator

The current ledger marks this instrument verified clean within the source-bound verification corpus.

Status: VERIFIED_CLEANLifecycle: verified-clean

Inspectable records

Ledger state

The current ledger marks this instrument verified clean within the source-bound verification corpus.

Area
Chemistry & Materials
Tranche
tranche-6
Evidence ID
t6-028
Ledger rows
1

No ledger note is attached.

Review findings

The arithmetic formula is correct, and the stated legacy-unit label is appropriate. Review is required because automatic lookup from an acid/base formula is underspecified for endpoint-dependent acid-base chemistry and medium-dependent redox chemistry.

Formula and scope findings

  • N = M × n_eq is the standard formula when M is mol/L and n_eq is the reaction-specific equivalents per mole.
  • An equivalence factor cannot always be determined from an acid/base formula alone: polyprotic acids such as H3PO4 have different factors depending on the titration endpoint.
  • Redox equivalence factors depend on the reaction and medium; for example, permanganate has different electron factors in acidic, neutral, and alkaline solution.
  • The lookup table must record the reaction context or endpoint, not only the chemical formula.

Unit assumptions

  • Molarity M is moles of solute per litre of final solution (mol/L).
  • The equivalence factor n_eq is equivalents per mole and is dimensionless as used in N = M × n_eq.
  • The output unit is equivalents per litre (eq/L), commonly written as normality (N).
  • If concentration is supplied in mmol/L, it must be converted to mol/L before applying the formula.
  • For acid-base reactions, the selected n_eq assumes a stated titration endpoint; for redox reactions, it assumes a stated medium and balanced reaction.

Boundary hardening

BREAK_CLAIMED · SELF_FLAGGED

The extreme-magnitude vector causes JavaScript multiplication to overflow: 1e308 × 1e308 becomes Infinity. The instrument should validate finite numeric inputs and reject or clearly report the non-finite result.

Errata and corrections

No applied erratum is attached to this unique-name record.

Inspectable example

4 review vectors are recorded. One source-bound sample is shown below.

{
  "inputs": {
    "solute": "HCl",
    "molarity": 0.1,
    "molarity_unit": "mol/L",
    "equivalence_factor": 1,
    "basis": "one H+ neutralized per HCl molecule"
  },
  "expected_outputs": {
    "normality": 0.1,
    "normality_unit": "eq/L"
  },
  "working": "N = M × n_eq = 0.1000 mol/L × 1 eq/mol = 0.1000 eq/L."
}

Related workflows

No source-defined multi-instrument workflow membership is recorded.

Sources and evidence

These pointers bind the page to evidence. They do not grant authority or collapse verification into deployment.

  • VERIFIED_LEDGER.json · VERIFIED_CLEAN
  • evidence-tranche6/tranche6-results.json
  • BOUNDARY_HAZARD_CATALOG.json