The current ledger marks this instrument verified clean within the source-bound verification corpus.
Inspectable records
Ledger state
The current ledger marks this instrument verified clean within the source-bound verification corpus.
- Area
- Chemistry & Materials
- Tranche
- tranche-7
- Evidence ID
- t7-044
- Ledger rows
- 1
No ledger note is attached.
Review findings
The arithmetic method is standard and valid after selecting a valid two-phase equilibrium tie line. The specification needs separate α+liquid and α+β formulas, explicit phase-field selection, composition basis, interpolation rules, boundary handling, and a defined convention for invariant points before it can receive PASS.
Formula and scope findings
- The stated formula fraction_α=(C_L-C_0)/(C_L-C_α) is correct only for an α+liquid two-phase field, with all compositions expressed on the same basis and C_α≤C_0≤C_L.
- The specification also claims α/β calculations, but the formula uses C_L and does not define the β fraction. For an α+β field, the required formula is fraction_α=(C_β-C_0)/(C_β-C_α), with fraction_β=(C_0-C_α)/(C_β-C_α).
- The temperature is not used directly by the arithmetic; it must select a valid equilibrium tie line from the phase-diagram dataset. The spec does not define interpolation, phase-field validation, or behavior at invariant points such as the eutectic.
- The requested tie-line diagram overlay cannot be verified from the stated arithmetic alone; plotting coordinates, axes, composition basis, and temperature-axis units must be specified.
Unit assumptions
- All compositions in these vectors are weight percent Sn, wt% Sn, on a Pb-Sn binary alloy basis; C0, Cα, and Cβ must use the same composition basis.
- Temperature is in degrees Celsius and selects the Pb-Sn eutectic tie-line. The tabulated eutectic values are used as the limiting α+β tie line just below the eutectic temperature.
- Phase fractions are dimensionless mass fractions and must sum to 1.0.
- The vectors exercise the α+β form of the lever rule, not the α+liquid form written in the specification.
Boundary hardening
BREAK_CLAIMED · SELF_FLAGGED
The formula produces an undefined 0/0 result when C_L equals C_alpha, and naive application outside the two-phase interval produces nonphysical fractions below zero or above one. Reversing endpoint or composition-axis conventions can also silently swap phase labels.
Errata and corrections
No applied erratum is attached to this unique-name record.
Inspectable example
4 review vectors are recorded. One source-bound sample is shown below.
{
"inputs": {
"system": "Pb-Sn",
"temperature_C": 182.99,
"overall_composition_wt_percent_Sn": 61.9,
"phase_field": "alpha+beta",
"C_alpha_wt_percent_Sn": 18.3,
"C_beta_wt_percent_Sn": 97.8
},
"expected_outputs": {
"phase_fractions": {
"alpha": 0.451572327,
"beta": 0.548427673
},
"sum": 1
},
"reference_data": {
"eutectic_temperature_C": 183,
"eutectic_composition_wt_percent_Sn": 61.9,
"C_alpha_wt_percent_Sn_at_eutectic": 18.3,
"C_beta_wt_percent_Sn_at_eutectic": 97.8,
"source_convention": "Widely tabulated standard value; ASM Alloy Phase Diagrams textbook compilation"
},
"working": "Use the α+β lever rule. Denominator = Cβ − Cα = 97.8 − 18.3 = 79.5 wt% Sn. Alpha fraction = (Cβ − C0)/(Cβ − Cα) = (97.8 − 61.9)/79.5 = 35.9/79.5 = 359/795 = 0.451572327. Beta fraction = (C0 − Cα)/(Cβ − Cα) = (61.9 − 18.3)/79.5 = 43.6/79.5 = 436/795 = 0.548427673. Check: 0.451572327 + 0.548427673 = 1.000000000."