# Pump Hydraulic Power Calculator

The current ledger marks this instrument verified clean within the source-bound verification corpus.

Status: **VERIFIED_CLEAN**Lifecycle: **verified-clean**

## Inspectable records

[01**Overview**Purpose and lifecycle](<https://guthlabs.ai/docs/instruments/pump-hydraulic-power-calculator/>)[02**Mechanism**Method and assumptions](<https://guthlabs.ai/docs/instruments/pump-hydraulic-power-calculator/mechanism/>)[03**Implementation**Binding and validation](<https://guthlabs.ai/docs/instruments/pump-hydraulic-power-calculator/implementation/>)[04**Qualification**Evidence and errata](<https://guthlabs.ai/docs/instruments/pump-hydraulic-power-calculator/qualification/>)

## Ledger state

The current ledger marks this instrument verified clean within the source-bound verification corpus.

**Area**: Thermodynamics, Fluids & Aero

**Tranche**: tranche-4

**Evidence ID**: t4-251

**Ledger rows**: 1

No ledger note is attached.

## Review findings

The two power formulas are correct under the stated SI-unit assumptions, but the specification needs explicit input units and validation constraints. The motor sizing output is undefined and should either be removed or given a documented formula and selection policy. An honest label should distinguish ideal hydraulic power, calculated pump shaft power, and actual motor electrical input.

### Formula and scope findings

- The hydraulic-power formula Phyd=ρgQH is standard when ρ is in kg/m³, g is in m/s², Q is in m³/s, and H is in m; it produces watts.

- The shaft-power formula Pshaft=Phyd/η is standard for pump efficiency expressed as a decimal fraction.

- The claimed motor sizing suggestion has no defined formula, motor-sizing rule, service factor, rounding convention, or output unit, so it cannot be verified or honestly generated from this specification.

- The flow-rate input unit is unspecified; using L/min, L/s, or m³/h directly without conversion would produce incorrect results.

### Unit assumptions

- g=9.81 m/s².

- Q must be converted to m³/s.

- H is total pump head in metres of fluid, not pressure in pascals or gauge pressure unless separately converted.

- ρ is fluid density in kg/m³.

- η is dimensionless pump efficiency represented as a decimal between 0 and 1, not a percentage.

- Phyd and Pshaft are returned in watts; kilowatts require division by 1000.

## Boundary hardening

**BREAK_CLAIMED** · SELF_FLAGGED

An efficiency input of η = 0 causes an undefined shaft-power result, and η = 1.2 is physically invalid despite producing a raw numeric result. Negative flow also produces opposite-signed power unless the convention is explicitly defined.

## Errata and corrections

No applied erratum is attached to this unique-name record.

## Inspectable example

4 review vectors are recorded. One source-bound sample is shown below.

````
{
  "inputs": {
    "Q_m3_s": 0.02,
    "H_m": 30,
    "rho_kg_m3": 998,
    "eta": 0.8
  },
  "expected_outputs": {
    "hydraulic_power_W": 5874.228,
    "shaft_power_W": 7342.785
  },
  "working": "Phyd=ρgQH=998×9.81×0.020×30. First, 9.81×0.020=0.1962. Then 0.1962×30=5.886. Then 5.886×998=5874.228 W. Pshaft=5874.228÷0.80=7342.785 W."
}
````

## Related workflows

[Pipe & Pump Benchpump](<https://guthlabs.ai/docs/instrument-workflows/pipe-pump/>)

## Sources and evidence

These pointers bind the page to evidence. They do not grant authority or collapse verification into deployment.

- `VERIFIED_LEDGER.json · VERIFIED_CLEAN`

- `evidence-tranche4/tranche4-results.json`

- `BOUNDARY_HAZARD_CATALOG.json`