Review findings
The core color-code lookup and resistance calculation are standard and correct for the tested 4-, 5-, and 6-band cases. Before release, define supported color-code conventions, mandatory encoder parameters, unit handling, invalid-input behavior, canonical rounding/E-series policy, and whether the product claims to encode 6-band temperature coefficients. The empty honest_label should be completed to state that reverse encoding may round or reject values and that any future camera recognition is not part of version 1.
Formula and scope findings
- The stated lookup-table method is standard, but the specification does not explicitly define the digit count: 4-band uses two significant digits, while 5-band and 6-band use three significant digits.
- For 6-band codes, the sixth band is a temperature-coefficient lookup and must be reported separately; it does not change the nominal resistance.
- Reverse encoding is underspecified: the required band count, tolerance, temperature coefficient, rounding policy, and preferred representation for values not exactly representable by a valid color code are not defined.
- The implementation must reject invalid band sequences, including unsupported colors, missing tolerance bands, negative or zero resistance inputs where not explicitly supported, and noncanonical significant-digit requests.
Unit assumptions
- Decoded resistance is reported in ohms unless a display-unit option is explicitly defined.
- Tolerance is expressed as percent and applies symmetrically to the nominal resistance: lower=R×(1−t/100), upper=R×(1+t/100).
- Encoder input units must be explicit; vector 4 uses kilohms and converts by 1 kΩ=1000 Ω before selecting bands.
- Temperature coefficient is expressed in ppm/K; numerically, ppm/K and ppm/°C increments are equivalent for a temperature difference.
Boundary hardening
BREAK_CLAIMED · SELF_FLAGGED
The extreme-value encoder input lies outside the supported EIA multiplier range and must be rejected explicitly. The decoder also has a convention hazard if band direction or the metallic tolerance band is not identified, and the exact-zero code should be flagged as a zero-ohm jumper rather than treated as an ordinary resistor.
Errata and corrections
No applied erratum is attached to this unique-name record.
Inspectable example
4 review vectors are recorded. One source-bound sample is shown below.
{
"inputs": {
"mode": "decode",
"band_colors": [
"brown",
"black",
"red",
"gold"
]
},
"expected_outputs": {
"nominal_resistance_ohms": 1000,
"tolerance_percent": 5,
"resistance_range_ohms": {
"min": 950,
"max": 1050
}
},
"reference_data": {
"digit_bands": [
{
"color": "brown",
"digit": 1,
"source_convention": "IEC 60062 / widely tabulated standard value"
},
{
"color": "black",
"digit": 0,
"source_convention": "IEC 60062 / widely tabulated standard value"
}
],
"multiplier_band": {
"color": "red",
"factor": 100,
"source_convention": "IEC 60062 / widely tabulated standard value"
},
"tolerance_band": {
"color": "gold",
"tolerance_percent": 5,
"source_convention": "IEC 60062 / widely tabulated standard value"
},
"table_entry": {
"color_code": "brown-black-red-gold",
"meaning": "1 kΩ ±5%",
"source_convention": "IEC 60062 / widely tabulated standard value"
}
},
"working": "4-band nominal value = (brown digit 1×10 + black digit 0)×red multiplier 100 = 10×100 = 1000 Ω. Tolerance = 1000×5/100 = 50 Ω. Minimum = 1000−50 = 950 Ω. Maximum = 1000+50 = 1050 Ω."