Reynolds Number for Blood Flow (biofluid mechanics)
The current ledger marks this instrument verified clean within the source-bound verification corpus.
Inspectable records
Ledger state
The current ledger marks this instrument verified clean within the source-bound verification corpus.
- Area
- Biology, Medicine & Pharmacology (educational estimates only — every panel labeled not-medical-advice)
- Tranche
- tranche-7
- Evidence ID
- t7-102
- Ledger rows
- 1
No ledger note is attached.
Review findings
The arithmetic formula is correct under the stated SI assumptions, but the instrument needs an explicit regime-threshold convention, a defined velocity type, and clearer preset provenance before it can be treated as fully specified. The density 1060 kg/m^3 and viscosity 3.5 mPa·s values are exact widely tabulated human-blood textbook presets used in all four vectors.
Formula and scope findings
- Re = ρvd/μ is the standard Reynolds-number formula for a Newtonian fluid when ρ, v, d, and μ are in mutually consistent units.
- The flow-regime algorithm is underspecified: no thresholds or treatment of the boundary values are provided. These test vectors use the common convention Re < 2000 = laminar, 2000 ≤ Re ≤ 4000 = transitional, and Re > 4000 = turbulent.
- Blood is non-Newtonian and flow is often pulsatile; using one fixed viscosity is an educational approximation and may not represent an apparent viscosity for a particular vessel, shear rate, temperature, or hematocrit.
- The specification does not define whether velocity means mean cross-sectional velocity, peak velocity, or another velocity measure. Reynolds number normally uses mean velocity for the stated vessel diameter.
Unit assumptions
- All calculations use SI units: density in kg/m^3, velocity in m/s, diameter in m, and dynamic viscosity in Pa·s.
- The standard preset values used here are human-blood density 1060 kg/m^3 and dynamic viscosity 3.5 mPa·s = 0.0035 Pa·s at approximately 37 °C.
- Diameter must be a vessel's internal diameter, not radius or external diameter.
- For regime labels, the convention used is laminar below Re 2000, transitional from Re 2000 through Re 4000 inclusive, and turbulent above Re 4000.
Boundary hardening
BREAK_CLAIMED · SELF_FLAGGED
The instrument breaks on zero viscosity because the Reynolds-number calculation is undefined and must be rejected. It also has a convention hazard for signed velocity and a classification discontinuity at the Re = 2300 regime threshold.
Errata and corrections
No applied erratum is attached to this unique-name record.
Inspectable example
4 review vectors are recorded. One source-bound sample is shown below.
{
"inputs": {
"vessel_diameter": 0.004,
"diameter_unit": "m",
"flow_velocity": 0.5,
"velocity_unit": "m/s",
"blood_density": 1060,
"density_unit": "kg/m^3",
"blood_viscosity": 0.0035,
"viscosity_unit": "Pa·s",
"temperature_C": 37
},
"expected_outputs": {
"reynolds_number": 605.7142857143,
"flow_regime": "laminar"
},
"reference_data": {
"blood_density_kg_m3_at_37C": {
"value": 1060,
"source_convention": "widely tabulated standard value (human-blood physiology/hemodynamics textbook convention)"
},
"blood_dynamic_viscosity_Pa_s_at_37C": {
"value": 0.0035,
"source_convention": "widely tabulated standard value (human-blood physiology/hemodynamics textbook convention)"
},
"regime_thresholds": {
"laminar": "Re < 2000",
"transitional": "2000 <= Re <= 4000",
"turbulent": "Re > 4000",
"source_convention": "widely tabulated standard engineering convention"
}
},
"working": "Re = ρvd/μ\n= (1060 kg/m^3 × 0.5 m/s × 0.004 m) / 0.0035 Pa·s\n= 2.12 / 0.0035\n= 605.7142857143.\nSince 605.7142857143 < 2000, the label is laminar."