curve_points pH@0 · vector 2
2.872327
2.875277
working computes x=0.001332671 correctly, then a WRONG 'Correction' drops Ka^2 under the root, concludes pH=2.875276 anyway — and the field ships 2.872327, matching neitherinstrument / verified-with-binding-errata
The current ledger marks this instrument verified with errata that must be applied at binding time.
The current ledger marks this instrument verified with errata that must be applied at binding time.
No ledger note is attached.
The supplied formulas are directionally standard for a monoprotic weak acid titrated by a strong base, but they do not fully specify the advertised instrument. The exact ambiguity requiring review is the unsupported meaning of 'strong/weak combinations' and the absence of a defined treatment for weak-base/strong-acid and weak/weak titrations. One arithmetic correction is important in the weak-acid and weak-base vectors: the exact initial quadratic result is 0.00133267 M, giving pH 2.87528 for the weak acid and pH 11.1247 for the weak base.
BREAK_CLAIMED · SELF_FLAGGED
The zero-concentration titrant case creates a genuine division-by-zero in equivalence-volume calculation and must be rejected. The zero-volume boundary also exposes a likely log10(0) failure if the pre-equivalence Henderson-Hasselbalch formula is applied at the initial point. Volume-direction conventions require explicit handling.
curve_points pH@0 · vector 2
2.872327
2.875277
working computes x=0.001332671 correctly, then a WRONG 'Correction' drops Ka^2 under the root, concludes pH=2.875276 anyway — and the field ships 2.872327, matching neithercurve_points pH@10.1 · vector 4
10.954243
10.954677
micro: [OH-]=1e-5/0.0111 rounded to 9.0e-4 before the log4 review vectors are recorded. One source-bound sample is shown below.
{
"inputs": {
"analyte": {
"type": "strong_acid",
"formula": "HCl",
"concentration_M": 0.1,
"volume_mL": 25
},
"titrant": {
"type": "strong_base",
"formula": "NaOH",
"concentration_M": 0.1
},
"sampled_volumes_mL": [
0,
12.5,
25,
30
]
},
"expected_outputs": {
"curve_points": [
{
"volume_mL": 0,
"pH": 1
},
{
"volume_mL": 12.5,
"pH": 1.477121
},
{
"volume_mL": 25,
"pH": 7
},
{
"volume_mL": 30,
"pH": 11.958607
}
],
"equivalence_volume_mL": 25,
"half_equivalence_volume_mL": 12.5,
"half_equivalence_pH": 1.477121,
"key_features": {
"equivalence_point": "pH 7.000000 under the 25 C ideal strong/strong assumption",
"half_equivalence_note": "pH is not pKa; the analyte is a strong acid"
}
},
"working": "Initial acid moles = 0.100 mol/L * 0.0250 L = 0.002500 mol. Equivalence volume = 0.002500 mol / 0.100 mol/L = 0.0250 L = 25.0 mL. At 0 mL: [H+]=0.100, so pH=-log10(0.100)=1.000000. At 12.5 mL: OH- moles=0.100*0.0125=0.001250 mol; remaining H+ moles=0.002500-0.001250=0.001250 mol; total volume=0.0375 L; [H+]=0.001250/0.0375=0.0333333; pH=-log10(0.0333333)=1.477121. At 25.0 mL, strong acid and strong base exactly neutralize, so pH=7.000000. At 30.0 mL: excess OH- moles=0.100*0.0300-0.002500=0.000500 mol; total volume=0.0550 L; [OH-]=0.000500/0.0550=0.00909091; pOH=-log10(0.00909091)=2.041393; pH=14.000000-2.041393=11.958607."
}No source-defined multi-instrument workflow membership is recorded.
These pointers bind the page to evidence. They do not grant authority or collapse verification into deployment.
VERIFIED_LEDGER.json · VERIFIED_WITH_ERRATAevidence-tranche6/tranche6-results.jsonBOUNDARY_HAZARD_CATALOG.json