# Weld Group (Line) Property Calculator

The current ledger marks this instrument verified clean within the source-bound verification corpus.

Status: **VERIFIED_CLEAN**Lifecycle: **verified-clean**

## Inspectable records

[01**Overview**Purpose and lifecycle](<https://guthlabs.ai/docs/instruments/weld-group-line-property-calculator/>)[02**Mechanism**Method and assumptions](<https://guthlabs.ai/docs/instruments/weld-group-line-property-calculator/mechanism/>)[03**Implementation**Binding and validation](<https://guthlabs.ai/docs/instruments/weld-group-line-property-calculator/implementation/>)[04**Qualification**Evidence and errata](<https://guthlabs.ai/docs/instruments/weld-group-line-property-calculator/qualification/>)

## Ledger state

The current ledger marks this instrument verified clean within the source-bound verification corpus.

**Area**: Mechanical, Civil & Structural Engineering — Statics/Dynamics, Strength of Materials, Machine Design, Civil, HVAC, Vibration

**Tranche**: tranche-5

**Evidence ID**: t5-053

**Ledger rows**: 1

No ledger note is attached.

## Review findings

NEEDS_REVIEW because the supplied formula is incomplete and Ju, axis conventions, units, centroid handling, and segment rules are ambiguous. The four vectors use an explicit standard interpretation: uniform zero-width weld lines, centroidal geometric properties, u-axis along global x, Iu=∫(y-yc)²ds, and Ju=∫[(x-xc)²+(y-yc)²]ds. The honest label should state that these are idealized line-group geometric properties, not weld capacity or stress results, and should identify the output units as length³.

### Formula and scope findings

- The stated formula "Iu=bd²/2+..." is incomplete: variables, axis definition, segment-orientation terms, centroidal shift terms, and summation rules are undefined.

- "Ju similar for torsion" is not a formula. For a line weld group, the standard centroidal polar line property is Ju=Iu+Iv, with Ju=∫[(x-xc)²+(y-yc)²]ds.

- The specification does not define whether Iu and Ju are geometric line properties with units of length³, normalized properties, or properties including weld throat thickness.

- AISC weld-as-line tables use specific axis and geometry conventions; the cited shorthand cannot verify arbitrary line-segment geometry without an explicit general formula.

- The centroid formula and handling of disconnected, intersecting, overlapping, or zero-length segments are not specified.

### Unit assumptions

- The test vectors interpret each weld as a zero-width line with uniform unit line density, so Iu, Iv, and Ju have units of length³.

- The u-axis is the global x-axis; therefore Iu=∫(y-yc)²ds.

- The perpendicular line property is Iv=∫(x-xc)²ds, and Ju=Iu+Iv.

- For a segment of length L, its own contribution about a parallel centroidal axis is L³/12; parallel-axis offsets use Ld².

- Centroid coordinates are length-weighted: xc=Σ(Li x̄i)/ΣLi and yc=Σ(Li ȳi)/ΣLi.

- Input coordinates and output properties use the declared input length unit; no automatic inch-to-millimetre conversion is assumed.

## Boundary hardening

**BREAK_CLAIMED** · SELF_FLAGGED

An empty weld pattern has total line length zero, so centroid, Iu, and Ju about that centroid are undefined. The calculator must reject the input rather than return numeric values or propagate NaN silently.

## Errata and corrections

No applied erratum is attached to this unique-name record.

## Inspectable example

4 review vectors are recorded. One source-bound sample is shown below.

````
{
  "inputs": {
    "units": "mm",
    "u_axis": "x",
    "segments": [
      {
        "start": [
          0,
          0
        ],
        "end": [
          100,
          0
        ]
      }
    ]
  },
  "expected_outputs": {
    "centroid": [
      50,
      0
    ],
    "Iu_mm3": 0,
    "Ju_mm3": 83333.333333
  },
  "working": "Segment length L=100 mm. Centroid=(0+100)/2,(0+0)/2=(50,0) mm. Iu=∫y² ds=100×0²=0 mm³. Ju=∫(x-50)²dx=100³/12=1000000/12=83333.333333 mm³."
}
````

## Related workflows

No source-defined multi-instrument workflow membership is recorded.

## Sources and evidence

These pointers bind the page to evidence. They do not grant authority or collapse verification into deployment.

- `VERIFIED_LEDGER.json · VERIFIED_CLEAN`

- `evidence-tranche5/tranche5-results.json`

- `BOUNDARY_HAZARD_CATALOG.json`