Page actions
instrument / verified-clean
Basal Insulin / Carb Ratio Reference (education)
The current ledger marks this instrument verified clean within the source-bound verification corpus.
Inspectable records
Ledger state
The current ledger marks this instrument verified clean within the source-bound verification corpus.
- Area
- Biology, Medicine & Pharmacology (educational estimates only — every panel labeled not-medical-advice)
- Tranche
- tranche-5
- Evidence ID
- t5-078
- Ledger rows
- 1
No ledger note is attached.
Review findings
The arithmetic formula passes dimensional review only under the stated unit and positivity assumptions. Because glucose units, validation constraints, negative-dose behavior, rounding, and the basal-versus-bolus naming issue are not fully specified, the catalog entry needs review before release.
Formula and scope findings
- The formula is standard for an illustrative rapid-acting insulin bolus estimate when carbs are in grams, InsulinCarbRatio is grams per unit, and CorrectionFactor is glucose units per unit of insulin; it does not calculate basal insulin despite the instrument name.
- The specification does not define glucose units. BG, Target, and CorrectionFactor must all use the same scale, such as mg/dL and mg/dL per unit or mmol/L and mmol/L per unit.
- The formula does not specify handling for negative calculated boluses, rounding, minimum doses, or whether a negative correction should be omitted or reduced under clinical instructions.
Unit assumptions
- carbs is grams of carbohydrate.
- InsulinCarbRatio is grams of carbohydrate per insulin unit and must be greater than zero.
- Current BG and Target BG use the same glucose unit.
- CorrectionFactor is glucose units per insulin unit and must be greater than zero.
- The resulting Bolus is in insulin units.
- Example glucose values use either mg/dL with mg/dL per unit or mmol/L with mmol/L per unit; the two systems must not be mixed.
Boundary hardening
BREAK_CLAIMED · SELF_FLAGGED
A zero insulin-to-carbohydrate ratio produces division by zero and an undefined bolus. The instrument should reject this input explicitly; returning a numeric result would be a safety-relevant failure of input validation.
Errata and corrections
No applied erratum is attached to this unique-name record.
Inspectable example
4 review vectors are recorded. One source-bound sample is shown below.
{
"inputs": {
"carbs_g": 60,
"insulin_carb_ratio_g_per_unit": 10,
"current_bg_mg_per_dL": 180,
"target_bg_mg_per_dL": 100,
"correction_factor_mg_per_dL_per_unit": 50
},
"expected_outputs": {
"illustrative_bolus_units": 7.6
},
"working": "Carb component = 60 / 10 = 6 units. Correction component = (180 - 100) / 50 = 80 / 50 = 1.6 units. Total = 6 + 1.6 = 7.6 units."
}Related workflows
No source-defined multi-instrument workflow membership is recorded.
Sources and evidence
These pointers bind the page to evidence. They do not grant authority or collapse verification into deployment.
VERIFIED_LEDGER.json · VERIFIED_CLEANevidence-tranche5/tranche5-results.jsonBOUNDARY_HAZARD_CATALOG.json