Chemistry Unit & Constants Converter mechanism
The inspectable method record for Chemistry Unit & Constants Converter, kept separate from implementation and qualification.
Model scope
The core concept is valid, but the instrument cannot be verified as fully specified until its conversion-factor table, CODATA edition, citation policy, aliases, ambiguity handling, and rounding/significant-figure rules are fixed. The test vectors use explicit unit conventions and CODATA 2018 for u; changing the adopted source requires updating the corresponding expected value.
- The stated linear-conversion approach is correct, but the specification does not define the authoritative numerical conversion table, precision, or rounding policy.
- Constants lookup is underspecified: no CODATA edition or other source/version is named, so values and citations may change between releases.
- The instrument must distinguish thermochemical calorie (cal_th), international table calorie, and food calorie/kilocalorie; plain "cal" is ambiguous.
- The instrument must distinguish unified atomic mass unit (u/Da) from historical or context-specific uses of "amu" and specify the adopted value and source.
- The output requirement says constants include a source citation, but the source-citation format and required citation metadata are not specified.
Units and conventions
- Use 1 atm = 101.325 kPa exactly; 1 bar = 100 kPa exactly; 1 atm = 760 torr exactly; for ordinary chemistry conversion, treat 1 torr and 1 mmHg as numerically equivalent, while labeling that convention explicitly.
- Use 1 cal_th = 4.184 J exactly. Do not interpret an unqualified "cal" as food Calorie/kcal.
- Use the CODATA 2018 conventional value for the unified atomic mass constant: 1 u = 1.66053906660e-27 kg; the selected CODATA edition must be displayed.
- Use the exact SI-defined Avogadro constant N_A = 6.02214076e23 mol^-1, with citation to the BIPM SI Brochure or an equivalent authoritative SI source.
- Values are interpreted as pure numbers in the stated units; output rounding and significant-figure behavior must be specified by the implementation.
Inspectable vector
One of 4 source-bound review vectors:
{
"inputs": {
"value": 1,
"from_unit": "atm",
"to_units": [
"kPa",
"mmHg",
"torr",
"bar"
]
},
"expected_outputs": {
"kPa": 101.325,
"mmHg": 760,
"torr": 760,
"bar": 1.01325
},
"working": "1 atm × (101.325 kPa/atm) = 101.325 kPa. 1 atm × (760 mmHg/atm) = 760 mmHg. 1 atm × (760 torr/atm) = 760 torr. 1 atm × (101.325 kPa/atm) × (1 bar/100 kPa) = 1.01325 bar."
}Failure boundary
BREAK_CLAIMED · SELF_FLAGGED
An unrecognized constant name produces an undefined lookup result and must be rejected explicitly. In addition, an unqualified pressure input cannot distinguish absolute pressure from gauge pressure without a convention warning.
Other records
Sources and evidence
These pointers bind the page to evidence. They do not grant authority or collapse verification into deployment.
VERIFIED_LEDGER.jsonevidence-tranche6/tranche6-results.jsonBOUNDARY_HAZARD_CATALOG.json