instrument qualification / verified-with-binding-errata

Converging-Diverging Nozzle Area-Ratio Calculator qualification

Verified with errata that must be applied at binding time.

Status: VERIFIED_WITH_ERRATALifecycle: verified-with-binding-errata

Ledger verdict

Verified with errata that must be applied at binding time.

Status
VERIFIED_WITH_ERRATA
Tranche
tranche-6
Review vectors
4
Ledger rows
1

Applied errata

[
  {
    "vector": "1,2,3",
    "field": "critical_choking_pressure_ratio_Pb_over_P0",
    "wrong": 0.528282,
    "correct": "0.93716 for AR=2 (p at the subsonic-exit solution; per-AR for others)",
    "cause": "ships the throat ratio (2/(g+1))^(g/(g-1)) as the choking BACK pressure — the classic misconception; a C-D nozzle chokes when Pb drops below the subsonic-branch exit pressure, not p*/P0 (v4 with AR=1 coincidentally agrees)"
  }
]

Adversarial re-test context

The full catalog was re-tested from boundary, convention, and self-check angles in 2,787 requests. Five genuine computational defects were independently verified and corrected. This page reports the current ledger state for this instrument; it does not imply product deployment or interface qualification.

Release gate

Bind every attached correction, replay the affected vectors, enforce boundary validation, and preserve evidence before describing the executable surface as qualified.