Creatinine Clearance (Cockcroft-Gault) mechanism
The inspectable method record for Creatinine Clearance (Cockcroft-Gault), kept separate from implementation and qualification.
Model scope
NEEDS_REVIEW because the exact weight convention and the allowed/meaningful sex categories are ambiguous. The educational, not-medical-advice label is appropriate, but the interface should also explicitly distinguish estimated Cockcroft-Gault creatinine clearance from eGFR and enforce positive SCr, positive weight, and valid age constraints.
- The algebraic formula is the standard Cockcroft-Gault form when age is in years, weight is in kg, and serum creatinine is in mg/dL.
- The weight definition is unspecified: actual body weight, ideal body weight, or adjusted body weight may be selected clinically depending on body composition and institutional dosing policy.
- The sex adjustment is represented only as a binary 0.85 multiplier; the applicable sex category and handling of patients who do not fit that binary input are unspecified.
- The formula does not state an applicable age range or constraints for physiologically valid inputs.
Units and conventions
- Age is measured in completed years.
- Weight is measured in kilograms.
- Serum creatinine (SCr) is measured in mg/dL; a value reported in µmol/L must be divided by 88.4 before use.
- The resulting CrCl is reported in mL/min without automatic normalization to body-surface area.
- The 0.85 multiplier is applied for female input and 1.00 otherwise, subject to the sex-category ambiguity noted above.
Inspectable vector
One of 4 source-bound review vectors:
{
"inputs": {
"age_years": 50,
"weight_kg": 70,
"sex": "male",
"serum_creatinine_mg_dL": 1
},
"expected_outputs": {
"creatinine_clearance_mL_min": 87.5
},
"working": "140 − 50 = 90; 90 × 70 = 6300; female factor = 1.00; denominator = 72 × 1.0 = 72; CrCl = 6300 ÷ 72 = 87.5 mL/min."
}Failure boundary
BREAK_CLAIMED · SELF_FLAGGED
A serum creatinine input of exactly zero produces division by zero, so the instrument must reject the input or return an explicit undefined result rather than a numeric clearance.
Other records
Sources and evidence
These pointers bind the page to evidence. They do not grant authority or collapse verification into deployment.