eGFR (CKD-EPI 2021, race-free) implementation
A source-bound implementation contract for eGFR (CKD-EPI 2021, race-free); deployment and executable qualification remain separate.
Binding contract
This record describes what an executable surface must bind and validate. It does not claim that a public calculator, package, or production route is deployed.
- Record owner
- Guth Instruments
- Lifecycle
- verified-clean
- Evidence ID
- t4-014
- Effect
- Computation or source lookup only
Input and validation requirements
A serum creatinine input of exactly 0 causes the negative power 0^(-0.302), producing an undefined or non-finite result. The instrument should reject this input instead of assigning an eGFR or CKD stage.
Required corrections
No binding erratum is attached to this unique-name record. Implementers must still preserve the declared units, domain, and failure behavior.
Inspectable interface fixture
The sample below is evidence for interface and validation tests, not a production implementation.
{
"inputs": {
"age_years": 40,
"sex": "male",
"serum_creatinine_mg_dL": 0.9
},
"expected_outputs": {
"eGFR_mL_min_1_73m2": 110.73,
"stage_label": "G1"
},
"working": "Male: k = 0.9, alpha = -0.302. SCr/k = 0.9/0.9 = 1. Therefore min(1,1)^(-0.302) = 1 and max(1,1)^(-1.200) = 1. Age factor = 0.9938^40 = 0.77976. eGFR = 142 × 1 × 1 × 0.77976 = 110.73 mL/min/1.73 m². Since 110.73 >= 90, the eGFR category is G1."
}Other records