Fourier Conduction (Plane Wall) Calculator
The current ledger marks this instrument verified clean within the source-bound verification corpus.
Inspectable records
Ledger state
The current ledger marks this instrument verified clean within the source-bound verification corpus.
- Area
- Thermodynamics, Fluids & Aero
- Tranche
- tranche-4
- Evidence ID
- t4-108
- Ledger rows
- 1
No ledger note is attached.
Review findings
The core formula is standard and correct under the stated steady-state 1D plane-wall idealization. The specification needs an explicit heat-flux formula, SI-unit requirements or documented unit conversion, a ΔT sign convention, and input constraints before release.
Formula and scope findings
- The heat-rate formula q = k·A·ΔT/L is correct for steady, one-dimensional conduction through a plane wall with constant thermal conductivity and no internal heat generation.
- The advertised heat-flux output has no explicit formula; it should be q'' = q/A = k·ΔT/L.
- The sign convention for ΔT is unspecified. For signed heat rate, define ΔT = T_hot − T_cold; otherwise the calculator should state that it reports heat-rate magnitude.
Unit assumptions
- Use SI units: k in W/(m·K), area A in m², thickness L in m, and ΔT in K or °C temperature difference; the result q is in W.
- Heat flux q'' is in W/m².
- If non-SI inputs are accepted, the calculator must explicitly convert area and thickness before applying the formula; the current specification does not state whether unit conversion is supported.
- Thermal-conductivity table entries must be in W/(m·K) or be converted to those units.
Boundary hardening
BREAK_CLAIMED · SELF_FLAGGED
The zero-thickness input produces an undefined division-by-zero result and must be rejected. The specification also leaves the sign convention for ΔT and heat-flow direction unstated, allowing results that differ by sign.
Errata and corrections
No applied erratum is attached to this unique-name record.
Inspectable example
4 review vectors are recorded. One source-bound sample is shown below.
{
"inputs": {
"k_W_per_mK": 0.6,
"area_m2": 2.5,
"thickness_m": 0.1,
"delta_T_K": 20
},
"expected_outputs": {
"heat_rate_q_W": 300,
"heat_flux_W_per_m2": 120
},
"working": "q = k·A·ΔT/L = 0.6·2.5·20/0.1 = 30/0.1 = 300 W. q'' = q/A = 300/2.5 = 120 W/m²."