Page actions
instrument implementation / implementation-contract
Heat Sink Thermal Resistance Calculator implementation
A source-bound implementation contract for Heat Sink Thermal Resistance Calculator; deployment and executable qualification remain separate.
Binding contract
This record describes what an executable surface must bind and validate. It does not claim that a public calculator, package, or production route is deployed.
- Record owner
- Guth Instruments
- Lifecycle
- verified-clean
- Evidence ID
- t4-290
- Effect
- Computation or source lookup only
Input and validation requirements
The specified output includes margin to Tj(max), but the specification provides no Tj(max) input or fixed value, making that output undefined. Additionally, sufficiently large finite JavaScript inputs overflow Tj to Infinity.
Required corrections
No binding erratum is attached to this unique-name record. Implementers must still preserve the declared units, domain, and failure behavior.
Inspectable interface fixture
The sample below is evidence for interface and validation tests, not a production implementation.
{
"inputs": {
"Ta": 25,
"Ta_unit": "°C",
"P": 10,
"thetaJC": 1.2,
"thetaCS": 0.3,
"thetaSA": 4.5,
"theta_unit": "°C/W",
"Tj_max": 125,
"Tj_max_unit": "°C"
},
"expected_outputs": {
"Tj": 85,
"Tj_unit": "°C",
"margin_to_Tj_max": 40,
"margin_unit": "°C"
},
"working": "θtotal = 1.2 + 0.3 + 4.5 = 6.0 °C/W. Temperature rise = 10 W × 6.0 °C/W = 60 °C. Tj = 25 °C + 60 °C = 85 °C. Margin = 125 °C − 85 °C = 40 °C."
}Other records
Sources and evidence
These pointers bind the page to evidence. They do not grant authority or collapse verification into deployment.
VERIFIED_LEDGER.jsonevidence-tranche4/tranche4-results.json