Page actions
instrument implementation / implementation-contract
Induction Motor Slip & Speed Calculator implementation
A source-bound implementation contract for Induction Motor Slip & Speed Calculator; deployment and executable qualification remain separate.
Binding contract
This record describes what an executable surface must bind and validate. It does not claim that a public calculator, package, or production route is deployed.
- Record owner
- Guth Instruments
- Lifecycle
- verified-clean
- Evidence ID
- t4-078
- Effect
- Computation or source lookup only
Input and validation requirements
A zero pole count produces division by zero in the synchronous-speed formula, so the calculator must reject that input. The specification does not state validation behavior, creating a potential undefined, Infinity, or NaN result.
Required corrections
No binding erratum is attached to this unique-name record. Implementers must still preserve the declared units, domain, and failure behavior.
Inspectable interface fixture
The sample below is evidence for interface and validation tests, not a production implementation.
{
"inputs": {
"frequency_Hz": 50,
"pole_count": 4,
"rotor_speed_rpm": 1440
},
"expected_outputs": {
"Ns_rpm": 1500,
"slip_percent": 4,
"rotor_frequency_Hz": 2
},
"working": "Ns = 120×50÷4 = 6000÷4 = 1500 rpm. Slip fraction = (1500−1440)÷1500 = 60÷1500 = 0.04. Slip percent = 0.04×100 = 4%. Rotor frequency = 0.04×50 = 2 Hz."
}Other records
Sources and evidence
These pointers bind the page to evidence. They do not grant authority or collapse verification into deployment.
VERIFIED_LEDGER.jsonevidence-tranche4/tranche4-results.json