Page actions
instrument implementation / implementation-contract
Linear Regulator Power Dissipation & Heatsink Need implementation
A source-bound implementation contract for Linear Regulator Power Dissipation & Heatsink Need; deployment and executable qualification remain separate.
Binding contract
This record describes what an executable surface must bind and validate. It does not claim that a public calculator, package, or production route is deployed.
- Record owner
- Guth Instruments
- Lifecycle
- verified-clean
- Evidence ID
- t4-279
- Effect
- Computation or source lookup only
Input and validation requirements
Extreme finite inputs overflow to Infinity, and the specification lacks ambient-temperature and maximum-junction-temperature limits needed for a definitive heatsink recommendation. Reverse-polarity/sign handling is also unspecified.
Required corrections
No binding erratum is attached to this unique-name record. Implementers must still preserve the declared units, domain, and failure behavior.
Inspectable interface fixture
The sample below is evidence for interface and validation tests, not a production implementation.
{
"inputs": {
"Vin_V": 12,
"Vout_V": 5,
"Iout_A": 0.5,
"thetaJA_C_per_W": 50
},
"expected_outputs": {
"Pd_W": 3.5,
"junction_temp_rise_C": 175,
"heatsink_recommendation": "Undetermined from the supplied formulas; requires ambient temperature and maximum junction temperature"
},
"working": "Voltage drop = 12−5 = 7 V. Pd = 7×0.5 = 3.5 W. Junction rise = 3.5×50 = 175 °C. A heatsink recommendation cannot be computed without T_A, T_J(max), and a defined decision threshold."
}Other records
Sources and evidence
These pointers bind the page to evidence. They do not grant authority or collapse verification into deployment.
VERIFIED_LEDGER.jsonevidence-tranche4/tranche4-results.json