The current ledger marks this instrument verified clean within the source-bound verification corpus.

Status: VERIFIED_CLEANLifecycle: verified-clean

Inspectable records

Ledger state

The current ledger marks this instrument verified clean within the source-bound verification corpus.

Area
Chemistry & Materials
Tranche
tranche-4
Evidence ID
t4-015
Ledger rows
1

No ledger note is attached.

Review findings

The core mole-fraction formula is correct. Review is required to define the mass+M input schema, supported units, whether direct moles and mass-based components can be mixed, validation behavior, and whether mole percent is also an output. The instrument should honestly label xᵢ as dimensionless mole fraction and should state that Σx = 1 only for a complete component list and a positive total amount.

Formula and scope findings

  • xᵢ = nᵢ/Σn is the standard mole-fraction formula when every nᵢ is an amount in moles. The stated alternative input 'mass+M' is underspecified because the required conversion nᵢ = mᵢ/Mᵢ is not included.
  • The specification does not state whether mass and molar mass must be supplied for every component or may be mixed with direct mole inputs.

Unit assumptions

  • All nᵢ values must be in moles before applying xᵢ = nᵢ/Σn.
  • For mass inputs, mᵢ and Mᵢ must use compatible units, such as grams and grams per mole or kilograms and kilograms per mole.
  • Molar masses must be positive; component amounts must be nonnegative.
  • The total amount Σn must be greater than zero.
  • Mole percent, if displayed, is 100xᵢ and should not be confused with the dimensionless mole fraction.

Boundary hardening

Recorded hazards

  • If all component amounts are zero, Σn = 0 and every mole fraction requires division by zero; the calculator must reject this input.
  • Negative amounts are physically invalid and must be rejected.
  • A zero molar mass causes division by zero in mass-to-mole conversion and must be rejected.
  • Incompatible mass and molar-mass units produce incorrect results unless converted first.
  • Floating-point rounding can make the displayed Σx differ slightly from 1; the check should use a documented tolerance.

Errata and corrections

No applied erratum is attached to this unique-name record.

Inspectable example

4 review vectors are recorded. One source-bound sample is shown below.

{
  "inputs": {
    "mode": "moles",
    "components": {
      "ethanol": 2,
      "water": 8
    }
  },
  "expected_outputs": {
    "x_ethanol": 0.2,
    "x_water": 0.8,
    "sum_x": 1
  },
  "working": "1. Sum the amounts: Σn = 2.0 mol + 8.0 mol = 10.0 mol. 2. Ethanol: x = 2.0/10.0 = 0.2. 3. Water: x = 8.0/10.0 = 0.8. 4. Check: Σx = 0.2 + 0.8 = 1.0."
}

Related workflows

No source-defined multi-instrument workflow membership is recorded.

Sources and evidence

These pointers bind the page to evidence. They do not grant authority or collapse verification into deployment.

  • VERIFIED_LEDGER.json · VERIFIED_CLEAN
  • evidence-tranche4/tranche4-results.json