Mutual Inductance / Coupled Coil Calculator mechanism
The inspectable method record for Mutual Inductance / Coupled Coil Calculator, kept separate from implementation and qualification.
Model scope
The formulas M = k*sqrt(L1*L2), Ltotal(aiding) = L1 + L2 + 2M, and Ltotal(opposing) = L1 + L2 - 2M are standard under the stated unit and polarity assumptions. Review is required because the input-unit policy, k sign/range, physical constraints, and honest user-facing limitations are not specified.
- The algebraic formulas are standard, but the sign convention for k is unspecified. If k is a nonnegative coupling magnitude, M is normally reported as a magnitude and the aiding/opposing choice supplies the sign. If k may be signed, the interaction between the sign of M and the aiding/opposing mode must be defined explicitly.
- The specification does not state that L1 and L2 must be positive finite self-inductances, or that the coupling coefficient must satisfy 0 <= k <= 1 for passive coupled coils.
Units and conventions
- L1 and L2 must use the same inductance unit before multiplication or addition; M and Ltotal use that same unit.
- k is dimensionless.
- sqrt(L1*L2) has the same inductance unit as L1 and L2 because both inductances use the same unit.
- The test vector with mixed H and mH explicitly converts all values to henries before calculation.
- Aiding and opposing refer to the relative winding-polarity/current-reference convention, not merely a numerical label.
Inspectable vector
One of 4 source-bound review vectors:
{
"inputs": {
"L1": 0.004,
"L1_unit": "H",
"L2": 0.009,
"L2_unit": "H",
"k": 0.5,
"connection": "series aiding"
},
"expected_outputs": {
"M": 0.003,
"M_unit": "H",
"Ltotal": 0.019,
"Ltotal_unit": "H"
},
"working": "M = k*sqrt(L1*L2) = 0.5*sqrt(0.004*0.009) = 0.5*sqrt(0.000036) = 0.5*0.006 = 0.003 H. Ltotal(aiding) = L1 + L2 + 2M = 0.004 + 0.009 + 2(0.003) = 0.004 + 0.009 + 0.006 = 0.019 H."
}Failure boundary
BREAK_CLAIMED · SELF_FLAGGED
The specification leaves the handling of negative inductances, signed coupling coefficients, and invalid square-root arguments unspecified. It can also produce different results if the sign of k and the aiding/opposing switch are both used to encode winding orientation.