Off-Grid Battery Bank Sizing (Solar) mechanism

The inspectable method record for Off-Grid Battery Bank Sizing (Solar), kept separate from implementation and qualification.

Status: VERIFIED_CLEANLifecycle: verified-clean

Model scope

The Ah equation is standard under its stated assumptions, but the unspecified efficiency definition and missing kWh formula prevent an unqualified PASS. The existing design-estimate label is appropriate; the instrument should also disclose that it is not a complete professional battery, inverter, conductor, protection, temperature, aging, or energy-harvesting design.

  • The Ah formula is conditionally standard: Ah = daily_load_Wh × autonomy_days ÷ (DoD × Vsystem × efficiency), assuming efficiency represents the total loss factor between nominal battery energy and delivered load energy. The efficiency definition and measurement point are unspecified.
  • The declared kWh output has no formula. If it means nominal battery-bank energy, the required formula is bank_kWh = required_Ah × Vsystem ÷ 1000. If it means usable or load-delivered energy, it will have a different value and must be labeled accordingly.
  • The formula does not specify whether daily load is measured at the AC loads, DC loads, inverter input, or battery terminals; this changes whether inverter and wiring losses belong in efficiency.

Units and conventions

  • daily_load_Wh is energy consumed per day in watt-hours, not load power in watts.
  • autonomy_days is in days.
  • DoD is a decimal fraction, such as 0.8 for 80%, not the integer 80.
  • Vsystem is volts and is consistent with the battery-bank nominal voltage.
  • efficiency is a dimensionless decimal fraction, such as 0.9 for 90%, and is greater than zero.
  • The reported bank_kWh in these vectors means nominal bank energy before DoD and efficiency losses: required_Ah × Vsystem ÷ 1000.

Inspectable vector

One of 4 source-bound review vectors:

{
  "inputs": {
    "daily_load_Wh": 3000,
    "autonomy_days": 2,
    "DoD": 0.8,
    "system_V": 48,
    "efficiency": 0.9
  },
  "expected_outputs": {
    "required_bank_Ah": 173.6111111111,
    "bank_kWh": 8.3333333333
  },
  "working": "Daily autonomy energy = 3000 Wh/day × 2 days = 6000 Wh. Denominator = 0.8 × 48 V × 0.9 = 34.56. Required Ah = 6000 ÷ 34.56 = 173.6111111111 Ah. Nominal bank energy = 173.6111111111 Ah × 48 V ÷ 1000 = 8.3333333333 kWh."
}

Failure boundary

BREAK_CLAIMED · SELF_FLAGGED

The formula is undefined when depth of discharge is zero, and the specification does not state required input validation. It also has no actual formula branches and leaves negative-load convention and efficiency range behavior ambiguous.

Other records

Sources and evidence

These pointers bind the page to evidence. They do not grant authority or collapse verification into deployment.

  • VERIFIED_LEDGER.json
  • evidence-tranche4/tranche4-results.json
  • BOUNDARY_HAZARD_CATALOG.json