Page actions
instrument implementation / implementation-contract
Open-Channel Flow — Manning's Equation implementation
A source-bound implementation contract for Open-Channel Flow — Manning's Equation; deployment and executable qualification remain separate.
Binding contract
This record describes what an executable surface must bind and validate. It does not claim that a public calculator, package, or production route is deployed.
- Record owner
- Guth Instruments
- Lifecycle
- verified-clean
- Evidence ID
- t6-120
- Effect
- Computation or source lookup only
Input and validation requirements
The specification has no stated validation for n=0 or negative slope. n=0 causes division by zero, while a signed negative slope makes the square-root argument invalid; both can produce undefined results unless rejected or assigned an explicit convention.
Required corrections
No binding erratum is attached to this unique-name record. Implementers must still preserve the declared units, domain, and failure behavior.
Inspectable interface fixture
The sample below is evidence for interface and validation tests, not a production implementation.
{
"inputs": {
"system": "SI",
"shape": "rectangular",
"width_m": 3,
"depth_m": 1,
"mannings_n": 0.025,
"slope": 0.001
},
"expected_outputs": {
"hydraulic_area_m2": 3,
"wetted_perimeter_m": 5,
"hydraulic_radius_m": 0.6,
"velocity_m_per_s": 0.899831,
"discharge_m3_per_s": 2.69949
},
"working": "A=b y=3*1=3 m^2. P=b+2y=3+2(1)=5 m. R=A/P=3/5=0.6 m. V=(1/0.025)(0.6)^(2/3)(0.001)^(1/2). (0.6)^(2/3)=0.711378661 and sqrt(0.001)=0.0316227766, so V=40*0.711378661*0.0316227766=0.8998307 m/s, or 0.899831 m/s. Q=VA=0.8998307*3=2.699492 m^3/s, or 2.69949 m^3/s."
}Other records
Sources and evidence
These pointers bind the page to evidence. They do not grant authority or collapse verification into deployment.
VERIFIED_LEDGER.jsonevidence-tranche6/tranche6-results.json