Review findings
The loss formulas are standard Darcy-Weisbach plus minor-loss relations under the stated SI assumptions, but the spec is not fully implementable without defining local velocity calculation, segment-specific K reference conditions, elevation sign convention, and the pump-head equation. The honest-label restriction to a single-path series run is appropriate and should remain explicit.
Formula and scope findings
- The friction and minor-loss terms are standard only when V is the local mean velocity for each segment: V_i=Q/(πD_i²/4). A single shared V is incorrect when segment diameters differ.
- The specification accepts flow rate Q but does not define how velocity V is derived from Q and each segment diameter.
- The required pump-head formula is not stated. Under the stated pressure-drop model it should be H_pump=ΔP_total/(ρg), subject to a clearly defined pressure and elevation sign convention.
- The elevation term ρgΔz is standard for static pressure change when Δz is outlet elevation minus inlet elevation; the sign convention is not specified.
- For fittings in segments with different diameters, each K must be multiplied by that fitting's local dynamic pressure ρV_i²/2, not by one common dynamic-pressure term.
Unit assumptions
- Use SI units: Q in m³/s, L and D in m, ρ in kg/m³, g=9.81 m/s², Δz in m, pressure in Pa, and pump head in m of the specified fluid.
- f and K are dimensionless Darcy friction factors and minor-loss coefficients.
- For each segment, V_i=Q/(πD_i²/4).
- Δz means outlet elevation minus inlet elevation; positive Δz increases the reported total pressure drop.
- Pump head is computed as H_pump=ΔP_total/(ρg), with no pump, motor, or efficiency losses included.
Boundary hardening
BREAK_CLAIMED · SELF_FLAGGED
A zero-diameter segment creates undefined area, velocity, and L/D terms. The calculator must reject it; accepting it without validation is a concrete failure mode. The branch test also exposes reliance on an unstated Reynolds-number friction-factor regime and threshold.
Errata and corrections
No applied erratum is attached to this unique-name record.
Inspectable example
4 review vectors are recorded. One source-bound sample is shown below.
{
"inputs": {
"flow_rate_m3_s": 0.01,
"rho_kg_m3": 1000,
"elevation_change_m": 2,
"g_m_s2": 9.81,
"segments": [
{
"length_m": 20,
"diameter_m": 0.1,
"friction_factor": 0.02,
"minor_loss_K": 1.5
}
]
},
"expected_outputs": {
"total_pressure_drop_Pa": 24078.13,
"required_pump_head_m": 2.45445
},
"working": "Area=π(0.1²)/4=0.00785398 m². V=0.01/0.00785398=1.27324 m/s. Dynamic pressure=ρV²/2=1000(1.27324²)/2=810.569 Pa. Friction coefficient=fL/D=0.02(20/0.1)=4. Minor coefficient=1.5. Friction plus minor loss=(4+1.5)(810.569)=4458.13 Pa. Elevation term=1000(9.81)(2)=19620 Pa. Total=4458.13+19620=24078.13 Pa. Pump head=24078.13/(1000·9.81)=2.45445 m."