Pump Hydraulic Power Calculator
The current ledger marks this instrument verified clean within the source-bound verification corpus.
Inspectable records
Ledger state
The current ledger marks this instrument verified clean within the source-bound verification corpus.
- Area
- Thermodynamics, Fluids & Aero
- Tranche
- tranche-4
- Evidence ID
- t4-251
- Ledger rows
- 1
No ledger note is attached.
Review findings
The two power formulas are correct under the stated SI-unit assumptions, but the specification needs explicit input units and validation constraints. The motor sizing output is undefined and should either be removed or given a documented formula and selection policy. An honest label should distinguish ideal hydraulic power, calculated pump shaft power, and actual motor electrical input.
Formula and scope findings
- The hydraulic-power formula Phyd=ρgQH is standard when ρ is in kg/m³, g is in m/s², Q is in m³/s, and H is in m; it produces watts.
- The shaft-power formula Pshaft=Phyd/η is standard for pump efficiency expressed as a decimal fraction.
- The claimed motor sizing suggestion has no defined formula, motor-sizing rule, service factor, rounding convention, or output unit, so it cannot be verified or honestly generated from this specification.
- The flow-rate input unit is unspecified; using L/min, L/s, or m³/h directly without conversion would produce incorrect results.
Unit assumptions
- g=9.81 m/s².
- Q must be converted to m³/s.
- H is total pump head in metres of fluid, not pressure in pascals or gauge pressure unless separately converted.
- ρ is fluid density in kg/m³.
- η is dimensionless pump efficiency represented as a decimal between 0 and 1, not a percentage.
- Phyd and Pshaft are returned in watts; kilowatts require division by 1000.
Boundary hardening
BREAK_CLAIMED · SELF_FLAGGED
An efficiency input of η = 0 causes an undefined shaft-power result, and η = 1.2 is physically invalid despite producing a raw numeric result. Negative flow also produces opposite-signed power unless the convention is explicitly defined.
Errata and corrections
No applied erratum is attached to this unique-name record.
Inspectable example
4 review vectors are recorded. One source-bound sample is shown below.
{
"inputs": {
"Q_m3_s": 0.02,
"H_m": 30,
"rho_kg_m3": 998,
"eta": 0.8
},
"expected_outputs": {
"hydraulic_power_W": 5874.228,
"shaft_power_W": 7342.785
},
"working": "Phyd=ρgQH=998×9.81×0.020×30. First, 9.81×0.020=0.1962. Then 0.1962×30=5.886. Then 5.886×998=5874.228 W. Pshaft=5874.228÷0.80=7342.785 W."
}Related workflows
Sources and evidence
These pointers bind the page to evidence. They do not grant authority or collapse verification into deployment.
VERIFIED_LEDGER.json · VERIFIED_CLEANevidence-tranche4/tranche4-results.jsonBOUNDARY_HAZARD_CATALOG.json