Guth
NewsDocs
Page actions
View as Markdown ↗
Explore MCP tools ↗

instrument implementation / implementation-contract

R-Value / U-Value Wall Assembly Calculator implementation

A source-bound implementation contract for R-Value / U-Value Wall Assembly Calculator; deployment and executable qualification remain separate.

Status: VERIFIED_CLEANLifecycle: implementation-contract

Binding contract

This record describes what an executable surface must bind and validate. It does not claim that a public calculator, package, or production route is deployed.

Record owner
Guth Instruments
Lifecycle
verified-clean
Evidence ID
t7-132
Effect
Computation or source lookup only

Input and validation requirements

The empty assembly with zero film resistance produces R_total = 0 and therefore an undefined U-value. The calculator must reject this input or explicitly report an undefined result. A separate unit-convention ambiguity can also produce materially different outputs if k is not dimensionally labeled.

Required corrections

No binding erratum is attached to this unique-name record. Implementers must still preserve the declared units, domain, and failure behavior.

Inspectable interface fixture

The sample below is evidence for interface and validation tests, not a production implementation.

{
  "inputs": {
    "layers": [
      {
        "material": "fiberglass batt",
        "thickness_m": 0.0127,
        "k_W_per_mK": 0.04
      }
    ],
    "R_si_m2K_per_W": 0.12,
    "R_se_m2K_per_W": 0.03
  },
  "expected_outputs": {
    "layer_resistances_m2K_per_W": [
      0.3175
    ],
    "R_total_m2K_per_W": 0.4675,
    "U_W_per_m2K": 2.1390374332
  },
  "reference_data": {
    "fiberglass_batt_k_W_per_mK": {
      "value": 0.04,
      "source_convention": "ASHRAE Fundamentals SI material-property table; widely tabulated standard value"
    },
    "R_si_m2K_per_W": {
      "value": 0.12,
      "source_convention": "ASHRAE Fundamentals standard interior surface-resistance convention"
    },
    "R_se_m2K_per_W": {
      "value": 0.03,
      "source_convention": "ASHRAE Fundamentals standard exterior surface-resistance convention"
    }
  },
  "working": "R_layer = thickness/k = 0.0127/0.04 = 0.3175 m^2*K/W. R_total = R_si + R_layer + R_se = 0.12 + 0.3175 + 0.03 = 0.4675 m^2*K/W. U = 1/R_total = 1/0.4675 = 2.1390374332 W/(m^2*K). The 0.04 W/(m*K) fiberglass conductivity is used exactly as the tabulated value."
}

Other records

Sources and evidence

These pointers bind the page to evidence. They do not grant authority or collapse verification into deployment.

  • VERIFIED_LEDGER.json
  • evidence-tranche7/tranche7-results.json