Rational Method Peak Runoff Calculator
The current ledger marks this instrument verified clean within the source-bound verification corpus.
Inspectable records
Ledger state
The current ledger marks this instrument verified clean within the source-bound verification corpus.
- Area
- Mechanical, Civil & Structural Engineering — Statics/Dynamics, Strength of Materials, Machine Design, Civil, HVAC, Vibration
- Tranche
- tranche-7
- Evidence ID
- t7-114
- Ledger rows
- 1
No ledger note is attached.
Review findings
The arithmetic and core Rational Method are valid under the stated unit assumptions. Verdict is NEEDS_REVIEW because the specification does not identify the local IDF source, return period, duration/time-of-concentration linkage, runoff-coefficient convention, interpolation policy, or jurisdiction-specific area limit. The honest label should say 'simplified Rational Method estimate for small, relatively homogeneous catchments' rather than treating 200 acres as a universal boundary.
Formula and scope findings
- Q=CiA is the standard Rational Method relationship, but the specification omits the unit-conversion constant. In SI units, Q(m^3/s)=C·i(mm/h)·A(ha)/360; in US customary units, Q(ft^3/s)=1.008333333·C·i(in/h)·A(acres).
- Rainfall intensity i must correspond to the catchment time of concentration and the selected return period; accepting arbitrary IDF intensity without those constraints can produce an invalid peak-flow estimate.
- C must be a dimensionless, bounded runoff coefficient, normally 0<=C<=1, selected for the actual surface, soil, slope, and antecedent conditions. The specification does not define how mixed surfaces are area-weighted.
- The stated '<200 acre' applicability limit is not universal. Rational Method limits vary by jurisdiction and project standard; some standards use much smaller limits or permit larger areas only with additional checks.
- The specification calls for runoff-coefficient and local-IDF tables but does not identify their editions, geographic applicability, return period, duration, or interpolation rules.
Unit assumptions
- Each vector explicitly states the intensity, area, and flow units; the production instrument must require an unambiguous unit system.
- C is dimensionless.
- For SI calculations, i is in mm/h, A is in hectares, and Q is in m^3/s, using the exact dimensional factor 1/360.
- For US customary calculations, i is in inches per hour, A is in acres, and Q is in ft^3/s, using 1 acre-inch per hour = 1.008333333 ft^3/s.
- IDF intensity values are assumed uniform over the catchment and applicable to a duration equal to the time of concentration.
Boundary hardening
BREAK_CLAIMED · SELF_FLAGGED
The specification has no unit-conversion or sign-convention definition, does not explicitly enforce the strict less-than-200-acre scope boundary, and permits extreme inputs that overflow ordinary arithmetic. It also has no true mathematical formula branch; only an applicability switch can be tested.
Errata and corrections
No applied erratum is attached to this unique-name record.
Inspectable example
4 review vectors are recorded. One source-bound sample is shown below.
{
"inputs": {
"C": 0.9,
"surface_type": "impervious roof",
"i": 100,
"i_units": "mm/h",
"A": 2,
"A_units": "ha",
"output_units": "m^3/s"
},
"expected_outputs": {
"Q": 0.5,
"Q_units": "m^3/s"
},
"reference_data": {
"runoff_coefficient": {
"surface_type": "impervious roof",
"C": 0.9,
"source_convention": "widely tabulated standard value (ASCE/municipal Rational Method tables)"
},
"rainfall_intensity": {
"duration": "local IDF duration equal to time of concentration",
"i_mm_per_h": 100,
"source_convention": "user-supplied local IDF data; geographic source and return period must be specified"
},
"si_conversion_factor": {
"value": 360,
"meaning": "Q(m^3/s)=C*i(mm/h)*A(ha)/360",
"source_convention": "SI dimensional conversion from hectare and millimetre per hour"
}
},
"working": "Q = C*i*A/360 = 0.90*100*2/360 = 180/360 = 0.500 m^3/s. The C=0.90 value is used exactly as the tabulated impervious-roof entry."
}Related workflows
No source-defined multi-instrument workflow membership is recorded.
Sources and evidence
These pointers bind the page to evidence. They do not grant authority or collapse verification into deployment.
VERIFIED_LEDGER.json · VERIFIED_CLEANevidence-tranche7/tranche7-results.jsonBOUNDARY_HAZARD_CATALOG.json