Page actions
instrument implementation / implementation-contract
Rebar Development Length Calculator implementation
A source-bound implementation contract for Rebar Development Length Calculator; deployment and executable qualification remain separate.
Binding contract
This record describes what an executable surface must bind and validate. It does not claim that a public calculator, package, or production route is deployed.
- Record owner
- Guth Instruments
- Lifecycle
- verified-clean
- Evidence ID
- t7-093
- Effect
- Computation or source lookup only
Input and validation requirements
The instrument has an undefined-result failure when c+Ktr=0, accepts a physically unacceptable zero-cover boundary, and can produce materially different results if Ktr sign convention is not enforced. Its branch condition for psi_t also requires an explicit top-bar placement rule.
Required corrections
No binding erratum is attached to this unique-name record. Implementers must still preserve the declared units, domain, and failure behavior.
Inspectable interface fixture
The sample below is evidence for interface and validation tests, not a production implementation.
{
"inputs": {
"bar_size": "#4",
"db_mm": 12.7,
"fy_MPa": 420,
"fc_MPa": 28,
"lambda": 1,
"psi_t": 1,
"psi_e": 1,
"psi_s": 1,
"c_b_mm": 31.75,
"Ktr_mm": 0,
"splice_type": "tension",
"splice_class": "B"
},
"expected_outputs": {
"ld_raw_mm": 30.24,
"ld_required_mm": 300,
"lap_splice_length_mm": 390
},
"reference_data": {
"bar_diameter_mm": {
"#4": 12.7
},
"bar_diameter_source_convention": "ACI 318-19 reinforcing-bar designation table; ASTM A615 standard bar-size value",
"fy_MPa": 420,
"fy_source_convention": "ASTM A615 Grade 60 minimum specified yield strength, widely tabulated standard value",
"fc_MPa": 28,
"fc_source_convention": "ACI 318-19 normalweight-concrete design-strength convention",
"minimum_tension_development_length_mm": 300,
"minimum_length_source_convention": "ACI 318-19 Ch.25, SI equivalent of 12 in minimum",
"class_B_lap_factor": 1.3,
"class_B_lap_source_convention": "ACI 318-19 tension lap-splice convention"
},
"working": "Corrected ACI SI equation: ld_raw = 0.075·(fy·ψt·ψe·ψs)/(λ·√f'c)·db/((cb+Ktr)/db). First, (cb+Ktr)/db = (31.75+0)/12.7 = 2.50. Then √28 = 5.29150. Then 0.075·420/(1.0·5.29150) = 5.95294. Then db/ratio = 12.7/2.50 = 5.08 mm. Therefore ld_raw = 5.95294·5.08 = 30.24 mm. Apply the 300 mm minimum: ld = max(30.24,300) = 300.00 mm. Class B lap splice = max(1.3·300.00,300) = max(390.00,300) = 390.00 mm."
}Other records
Sources and evidence
These pointers bind the page to evidence. They do not grant authority or collapse verification into deployment.
VERIFIED_LEDGER.jsonevidence-tranche7/tranche7-results.json