Sample Rate / Nyquist Frequency Checker mechanism
The inspectable method record for Sample Rate / Nyquist Frequency Checker, kept separate from implementation and qualification.
Status: VERIFIED_CLEANLifecycle: verified-clean
Model scope
The core arithmetic formula is correct under consistent frequency units. The instrument should be revised to define sample-rate units, reject nonpositive rates, clarify the Nyquist-boundary wording, and either remove the aliasing-check claim or add a signal-frequency input and explicit aliasing rule.
- fmax=fs/2 is the standard Nyquist-frequency formula, but the wording "maximum representable frequency" is potentially misleading: frequencies at or above fs/2 are not safely representable without qualification, and exactly fs/2 is a boundary case.
- The claimed aliasing check is not implemented by fmax=fs/2 alone. An aliasing check requires a signal/input frequency and a defined rule, such as flagging frequencies at or above fs/2.
- The common-rate table output is not explicitly defined as a formula or output schema, although its values can be generated by applying fmax=fs/2 to each listed rate.
Units and conventions
- The sample rate and resulting Nyquist frequency must use the same frequency unit.
- If sample rate is supplied in Hz, the output is in Hz; if supplied in kHz, the output is in kHz.
- The listed common rates mean 44.1 kHz, 48 kHz, 96 kHz, and 192 kHz, equivalent to 44100 Hz, 48000 Hz, 96000 Hz, and 192000 Hz.
- A clearly labeled unit field or a fixed input convention is required; the current spec only says "sample rate".
Inspectable vector
One of 4 source-bound review vectors:
{
"inputs": {
"sample_rate": 44100,
"sample_rate_unit": "Hz"
},
"expected_outputs": {
"nyquist_frequency": 22050,
"nyquist_frequency_unit": "Hz"
},
"working": "fmax = fs / 2 = 44100 Hz / 2 = 22050 Hz."
}Failure boundary
- A zero or negative sample rate is invalid and must be rejected; zero yields a mathematically defined result but no usable sampling capability.
- The implementation must avoid implying that a frequency exactly equal to fs/2 is generally safe to represent; use a boundary-aware label such as Nyquist limit or require frequency < fs/2.
- The aliasing claim is incomplete without a signal-frequency input and a comparison rule.
- Unit omission can cause a 1000-fold error, such as interpreting 44.1 kHz as 44.1 Hz.
- The common-rate table should explicitly state units and whether values are displayed in Hz or kHz.