The inspectable method record for Transmission Line / SWR Calculator, kept separate from implementation and qualification.
Model scope
The reflection-coefficient, VSWR, and return-loss formulas are standard under the stated real-positive-Z0 assumptions. The instrument cannot pass as specified because mismatch loss is claimed but not defined, and the power-input mode overclaims a complex reflection coefficient without phase information.
- The listed formulas omit mismatch loss, although mismatch loss is claimed as an output. The standard passive-load formula is ML=-10log10(1-|Γ|^2) dB, equivalently -10log10(P_transmitted/P_incident).
- The forward/reflected-power input path determines only |Γ|=sqrt(Pr/Pf); it cannot determine the complex reflection coefficient Γ without a reflection phase input.
- VSWR=(1+|Γ|)/(1-|Γ|) is valid for |Γ|<1. At |Γ|=1 it is infinite, and for |Γ|>1 it is not a physically valid passive-load VSWR result.
- The reflection-coefficient formula assumes a real, positive characteristic impedance Z0. If a complex reference impedance is intended, the reference-conjugation convention must be specified.
- Return loss is undefined/infinite at Γ=0 and requires an explicit UI/output convention for that case.
Units and conventions
- Z0 and ZL are impedances in the same units, conventionally ohms; their ratio is dimensionless.
- Z0 is assumed real and positive, and ZL may be complex in rectangular or polar form.
- Forward and reflected powers must use the same power units, such as both watts or both milliwatts; only their ratio is used.
- For power inputs, Pf must be positive and 0<=Pr<=Pf for a passive one-port.
- Angles in the complex-number UI must explicitly declare degrees or radians; the specification does not currently state which is used.
Inspectable vector
One of 4 source-bound review vectors:
{
"inputs": {
"Z0": "50 ohm",
"ZL": "100 + j0 ohm"
},
"expected_outputs": {
"reflection_coefficient": "1/3 + j0",
"reflection_magnitude": 0.3333333333333333,
"VSWR": 2,
"return_loss_dB": 9.542425094393248,
"mismatch_loss_dB": 0.511525224473813
},
"reference_data": {
"formulas": [
"Gamma=(ZL-Z0)/(ZL+Z0)",
"VSWR=(1+abs(Gamma))/(1-abs(Gamma))",
"RL=-20log10(abs(Gamma))",
"ML=-10log10(1-abs(Gamma)^2)"
]
},
"working": "Gamma=(100-50)/(100+50)=50/150=1/3. |Gamma|=1/3. VSWR=(1+1/3)/(1-1/3)=(4/3)/(2/3)=2. RL=-20log10(1/3)=20log10(3)=9.542425094393248 dB. ML=-10log10(1-1/9)=-10log10(8/9)=10log10(9/8)=0.511525224473813 dB."
}Failure boundary
BREAK_CLAIMED · SELF_FLAGGED
The specified formulas have singular or out-of-domain cases that require explicit validation: ZL=-Z0 causes division by zero, |Gamma|=1 makes VSWR and mismatch loss infinite, and |Gamma|>1 produces a negative raw VSWR and a non-real mismatch-loss logarithm. The complex-impedance convention can also reverse the sign of the imaginary part of Gamma.