UV Index Exposure Time Estimator mechanism
The inspectable method record for UV Index Exposure Time Estimator, kept separate from implementation and qualification.
Model scope
The supplied rule-of-thumb can be implemented only after explicitly choosing minutes and defining skin_factor as MED/200. It should be labeled as an educational erythema-threshold estimate, not a safe-exposure calculator. For a standards-based calculation, replace the heuristic with t_minutes = MED_J_per_m2/(1.5 × UV_index), while still retaining strong medical and individual-variability warnings.
- The stated formula is dimensionally ambiguous: the unit of 200 is not specified. The test calculations assume minutes, but the formula would produce a result 60 times smaller if interpreted as seconds.
- The formula is not the standard physical conversion from UV Index to erythemally weighted dose. Using 1 UVI = 0.025 W/m², time in minutes is MED_J_per_m2/(1.5 × UVI), so a 200 J/m² MED gives about 133.3/UVI minutes, not 200/UVI minutes.
- The formula requires an explicit definition of skin_factor. A defensible approximation is skin_factor = MED_for_type/200 J/m², but this is not stated in the specification.
- “Approximate safe exposure time” is misleading: the result estimates time to a possible erythema threshold, not a medically safe exposure duration.
- Fitzpatrick type alone cannot reliably predict individual erythema response; UV spectrum, altitude, cloud cover, reflection, sunscreen, clothing, medications, prior exposure, and individual variability are omitted.
Units and conventions
- UV Index is dimensionless.
- For the supplied rule-of-thumb test calculations, 200 is interpreted as 200 minutes for Fitzpatrick type I at UVI 1.
- skin_factor is interpreted as MED_for_skin_type divided by the type-I reference MED of 200 J/m².
- The MED table values are approximate erythemal doses in J/m², not guaranteed individual thresholds.
- If a physically derived result is desired instead, use 1 UVI = 0.025 W/m² and convert seconds to minutes explicitly.
Inspectable vector
One of 4 source-bound review vectors:
{
"inputs": {
"uv_index": 1,
"fitzpatrick_skin_type": "I"
},
"expected_outputs": {
"estimated_time_to_erythema_minutes": 200,
"estimated_time_to_erythema_seconds": 12000
},
"reference_data": {
"skin_type": "I",
"MED_J_per_m2": 200,
"skin_factor_relative_to_type_I": 1,
"rule_of_thumb_base_minutes": 200,
"source_convention": "MED value: widely tabulated standard Fitzpatrick educational convention; rule-of-thumb base: instrument-stated heuristic, not a medical or SI standard"
},
"working": "skin_factor = 200/200 = 1.\\nt_minutes = (200 min / 1) × 1 = 200 min.\\nt_seconds = 200 × 60 = 12,000 s."
}Failure boundary
BREAK_CLAIMED · SELF_FLAGGED
UV_index = 0 causes division by zero and must be rejected. Additionally, the required Fitzpatrick MED/skin-factor lookup table and output time unit are absent from the specification, so numerical results are conditional on assumed factors and a minutes convention.