Brayton Cycle Efficiency Calculator mechanism

The inspectable method record for Brayton Cycle Efficiency Calculator, kept separate from implementation and qualification.

Status: Verified in ledgerLifecycle: verified-clean

Model scope

The base simple-cycle efficiency formula is standard, but the specification is incomplete for its claimed outputs and does not define the regenerative efficiency adjustment. Verdict remains needs review until the missing work equations, regeneration model, temperature units, input constraints, and zero-denominator behavior are explicitly specified.

  • The base formula η=1−1/rp^((γ−1)/γ) is correct only for an ideal simple Brayton cycle with constant γ, isentropic compression and expansion, and no pressure losses.
  • No formula is provided for compressor-exit temperature, turbine-exit temperature, compressor work, turbine work, net specific work, or back-work ratio, even though those outputs are claimed.
  • The regenerative adjustment is unspecified: effectiveness ε alone does not define η without the regenerator temperature relations and heat-input definition.
  • A standard regeneration model must specify T2r=T2+ε(T4−T2), T4r=T4−ε(T4−T2), and η=(wt−wc)/qin, with qin=Cp(T3−T2r).
  • Regeneration is physically useful only when T4>T2; otherwise the regenerator should be bypassed or ε should be treated as zero.
  • The listed formula does not use turbine/compressor inlet temperatures or Cp, so it cannot by itself produce specific work or back-work ratio.

Units and conventions

  • Temperatures are absolute temperatures in kelvin for all thermodynamic formulas; Celsius or Fahrenheit values must be converted before multiplication or division.
  • Pressure ratio rp is dimensionless and means compressor outlet absolute pressure divided by compressor inlet absolute pressure.
  • γ is dimensionless and assumed constant, with γ>1; the examples use γ=1.4 for air.
  • Cp is assumed constant and expressed in kJ/(kg·K); the examples use Cp=1.005 kJ/(kg·K), so work outputs are in kJ/kg.
  • The test vectors use the standard ideal-cycle relations T2=T1·rp^((γ−1)/γ), T4=T3/rp^((γ−1)/γ), wc=Cp(T2−T1), wt=Cp(T3−T4), and wnet=wt−wc.
  • For regenerated cases, the standard no-pressure-loss regenerator model and ε between 0 and 1 are assumed.

Inspectable vector

One of 4 source-bound review vectors:

{
  "inputs": {
    "rp": 4,
    "gamma": 1.4,
    "T1_K": 288,
    "T3_K": 1400,
    "Cp_kJ_per_kgK": 1.005,
    "regeneration": false
  },
  "expected_outputs": {
    "eta": 0.32705,
    "specific_work_kJ_per_kg": 319.497,
    "back_work_ratio": 0.30569
  },
  "working": "a=(γ−1)/γ=0.4/1.4=2/7. F=rp^a=4^(2/7)=1.485994. T2=T1·F=288·1.485994=427.966 K. T4=T3/F=1400/1.485994=942.130 K. wc=Cp(T2−T1)=1.005·(427.966−288)=1.005·139.966=140.666 kJ/kg. wt=Cp(T3−T4)=1.005·(1400−942.130)=1.005·457.870=460.163 kJ/kg. wnet=wt−wc=460.163−140.666=319.497 kJ/kg. η=1−1/F=1−1/1.485994=0.32705. Back-work ratio=wc/wt=140.666/460.163=0.30569."
}

Failure boundary

  • Division by zero occurs for back-work ratio when turbine work is zero, including the rp=1 boundary case.
  • The exponent requires γ>1; γ=1 causes a degenerate zero-efficiency result, and γ≤1 is not a valid ordinary ideal-gas Brayton-cycle input.
  • rp must be positive; rp=0 is invalid and negative pressure ratios are nonphysical.
  • Regenerator effectiveness should be constrained to 0≤ε≤1.
  • The regenerator formula requires a specified operating condition such as T4>T2; applying regeneration when T4≤T2 can produce nonphysical heat flow or misleading efficiency.
  • If T3≤T2, the heat-addition denominator is zero or negative and efficiency is undefined or nonphysical.
  • Celsius inputs used directly instead of kelvin produce incorrect temperatures and work values.
  • Cp must be supplied or given a clearly documented default; changing Cp changes specific work but not the ideal simple-cycle efficiency.