Review findings
Formula verification passes for the two stated pure topologies, but the specification needs review because input units and the exact topology representation are unspecified. The empty honest_label is a concern: the instrument should clearly state that it supports only pure series or pure parallel networks unless mixed series/parallel reduction is implemented.
Formula and scope findings
- The formulas are standard and correct for a purely parallel network (Cp=ΣCi) or a purely series network (1/Cs=Σ1/Ci). They do not define how arbitrary mixed series/parallel topologies are represented or reduced.
- The series formula requires every capacitor value Ci to be nonzero; for physical capacitors, values should also be strictly positive.
Unit assumptions
- All capacitor values in a calculation must use one common unit, or the implementation must perform explicit unit conversion before summation or reciprocal calculation.
- The test outputs below are expressed in microfarads unless otherwise stated.
- Capacitance values are ideal lumped capacitances; parasitic effects, voltage dependence, tolerance, and frequency-dependent behavior are not included.
Boundary hardening
BREAK_CLAIMED · SELF_FLAGGED
A zero-valued capacitor in a series network creates a 1/0 undefined term, and omitted units create a convention-dependent result. Inputs should be validated and units made explicit.
Errata and corrections
No applied erratum is attached to this unique-name record.
Inspectable example
4 review vectors are recorded. One source-bound sample is shown below.
{
"inputs": {
"topology": "parallel",
"capacitors": [
{
"value": 10,
"unit": "uF"
},
{
"value": 22,
"unit": "uF"
}
]
},
"expected_outputs": {
"Ceq": 32,
"unit": "uF"
},
"working": "Cp = ΣCi = 10 uF + 22 uF = 32 uF."