Inductor Series/Parallel Combiner

The current ledger marks this instrument verified clean within the source-bound verification corpus.

Status: VERIFIED_CLEANLifecycle: verified-clean

Inspectable records

Ledger state

The current ledger marks this instrument verified clean within the source-bound verification corpus.

Area
Electrical & Electronics Engineering — Circuits, Power Systems, Electronics Lab
Tranche
tranche-5
Evidence ID
t5-128
Ledger rows
1

No ledger note is attached.

Review findings

The stated series and parallel formulas are standard for ideal uncoupled inductors. The honest label correctly identifies the no-mutual-coupling assumption. Verdict is NEEDS_REVIEW because input units and mixed-unit behavior are unspecified, and valid-input constraints are not documented.

Formula and scope findings

No additional record

Unit assumptions

  • All inductance values must use a common unit before applying either formula; the specification does not define an input-unit convention or mixed-unit handling.
  • The formulas assume ideal, uncoupled inductors with linear, frequency-independent inductance values.
  • For parallel combinations, each inductance must be nonzero; practical inductors also require compatible connection polarity and negligible parasitic effects.

Boundary hardening

BREAK_CLAIMED · SELF_FLAGGED

A parallel input containing a zero-valued inductor causes division by zero and must be rejected. Additionally, the input specification does not define a unit convention, so bare values can produce results differing by a factor of 1000 between mH and H.

Errata and corrections

No applied erratum is attached to this unique-name record.

Inspectable example

4 review vectors are recorded. One source-bound sample is shown below.

{
  "inputs": {
    "topology": "series",
    "inductors": [
      {
        "value": 10,
        "unit": "uH"
      },
      {
        "value": 22,
        "unit": "uH"
      },
      {
        "value": 47,
        "unit": "uH"
      }
    ]
  },
  "expected_outputs": {
    "Leq": 79,
    "unit": "uH"
  },
  "working": "Ls = ΣLi = 10 uH + 22 uH + 47 uH = 32 uH + 47 uH = 79 uH."
}