Page actions
instrument / verified-clean
Series/Parallel Resistor Combiner
The current ledger marks this instrument verified clean within the source-bound verification corpus.
Inspectable records
Ledger state
The current ledger marks this instrument verified clean within the source-bound verification corpus.
- Area
- Electrical & Electronics Engineering
- Tranche
- tranche-2
- Evidence ID
- t2-006
- Ledger rows
- 1
No ledger note is attached.
Review findings
The two stated formulas are standard for their respective simple topologies, but the spec is not complete enough to verify arbitrary series/parallel networks. The honest label is empty; it should state supported topology depth, accepted units, and handling of zero, empty, invalid, and non-finite resistor values.
Formula and scope findings
- Rs=ΣRi is correct for resistors connected strictly in series.
- 1/Rp=Σ1/Ri is correct for resistors connected strictly in parallel, provided every resistor value is nonzero and all values use the same resistance unit.
- The specification does not define how mixed or nested series/parallel topologies are represented or evaluated, so it does not fully specify computation of arbitrary series/parallel networks.
- The topology input is ambiguous: it does not state whether topology is limited to a single series or parallel group or can describe nested combinations.
Unit assumptions
- All resistor values in one calculation must use a common unit, such as all Ω or all kΩ; the resulting Req has that same unit.
- If values carry unit labels, the implementation must convert them to a common unit before applying the formulas.
- Resistor values are assumed to be real, positive values unless zero-ohm ideal shorts are explicitly supported.
Boundary hardening
BREAK_CLAIMED · SELF_FLAGGED
A zero-ohm resistor in a parallel network makes the reciprocal formula divide by zero, so the instrument must reject the input or implement an explicit ideal-short rule. Results also depend on an explicit resistance-unit convention.
Errata and corrections
No applied erratum is attached to this unique-name record.
Inspectable example
4 review vectors are recorded. One source-bound sample is shown below.
{
"inputs": {
"resistors": [
{
"value": 100,
"unit": "ohm"
},
{
"value": 220,
"unit": "ohm"
},
{
"value": 330,
"unit": "ohm"
}
],
"topology": "series"
},
"expected_outputs": {
"Req": {
"value": 650,
"unit": "ohm"
}
},
"working": "Rs = 100 Ω + 220 Ω + 330 Ω = 320 Ω + 330 Ω = 650 Ω."
}Related workflows
Sources and evidence
These pointers bind the page to evidence. They do not grant authority or collapse verification into deployment.