Duty Cycle / PWM Average Voltage Calculator implementation
A source-bound implementation contract for Duty Cycle / PWM Average Voltage Calculator; deployment and executable qualification remain separate.
Binding contract
This record describes what an executable surface must bind and validate. It does not claim that a public calculator, package, or production route is deployed.
- Record owner
- Guth Instruments
- Lifecycle
- verified-clean
- Evidence ID
- t5-216
- Effect
- Computation or source lookup only
Input and validation requirements
A zero-frequency input makes T=1/f a division by zero, leaving period and on/off times undefined. The instrument must reject frequency=0 rather than return a misleading numeric result. The specification also leaves the duty-cycle percent-versus-fraction convention implicit, creating a substantial interpretation hazard.
Required corrections
No binding erratum is attached to this unique-name record. Implementers must still preserve the declared units, domain, and failure behavior.
Inspectable interface fixture
The sample below is evidence for interface and validation tests, not a production implementation.
{
"inputs": {
"duty_cycle_percent": 25,
"Vhigh_V": 12,
"Vlow_V": 0,
"frequency_Hz": 1000
},
"expected_outputs": {
"Vavg_V": 3,
"period_s": 0.001,
"on_time_s": 0.00025,
"off_time_s": 0.00075
},
"working": "D=25/100=0.25. Vavg=D×Vhigh+(1−D)×Vlow=0.25×12+(1−0.25)×0=3+0=3 V. T=1/f=1/1000=0.001 s. Ton=D×T=0.25×0.001=0.00025 s. Toff=(1−D)×T=0.75×0.001=0.00075 s."