Page actions
instrument implementation / implementation-contract
eGFR (MDRD, legacy) implementation
A source-bound implementation contract for eGFR (MDRD, legacy); deployment and executable qualification remain separate.
Binding contract
This record describes what an executable surface must bind and validate. It does not claim that a public calculator, package, or production route is deployed.
- Record owner
- Guth Instruments
- Lifecycle
- verified-clean
- Evidence ID
- t4-026
- Effect
- Computation or source lookup only
Input and validation requirements
The formula has undefined or non-physiologic boundary inputs that require validation: age = 0 produces an infinite mathematical result, negative serum creatinine produces an undefined real power, and an unspecified creatinine unit can produce an orders-of-magnitude error.
Required corrections
No binding erratum is attached to this unique-name record. Implementers must still preserve the declared units, domain, and failure behavior.
Inspectable interface fixture
The sample below is evidence for interface and validation tests, not a production implementation.
{
"inputs": {
"age_years": 60,
"sex": "male",
"serum_creatinine_mg_dL": 1
},
"expected_outputs": {
"eGFR_mL_min_1_73m2": 76.22
},
"working": "SCr^-1.154 = 1.0^-1.154 = 1.000. Age^-0.203 = 60^-0.203 ≈ 0.43555. Male multiplier = 1.000. eGFR = 175 × 1.000 × 0.43555 × 1.000 = 76.22 mL/min/1.73 m²."
}Other records
Sources and evidence
These pointers bind the page to evidence. They do not grant authority or collapse verification into deployment.