Lung Capacity Predicted Values (Spirometry Reference)
The current ledger marks this instrument verified clean within the source-bound verification corpus.
Inspectable records
Ledger state
The current ledger marks this instrument verified clean within the source-bound verification corpus.
- Area
- Biology, Medicine & Pharmacology (educational estimates only — every panel labeled not-medical-advice)
- Tranche
- tranche-7
- Evidence ID
- t7-025
- Ledger rows
- 1
No ledger note is attached.
Review findings
The arithmetic fixtures verify only ratio and percentage post-processing using explicitly supplied provisional reference values. They do not verify the GLI-2012 demographic prediction itself. Before PASS, supply the authoritative GLI-2012 coefficient/table dataset, source/version, ethnic-group mapping, LMS equation including z=0 convention, valid ranges, interpolation rules, missing-data behavior, rounding policy, and an explicit decision on whether %predicted for FEV1/FVC is offered.
Formula and scope findings
- The specification names GLI-2012 but does not provide the required GLI-2012 LMS coefficients, spline knots, coefficient version, or calculation algorithm, so the claimed predictions cannot be independently reproduced from this specification.
- GLI-2012 is ordinarily implemented with sex-, age-, height-, and ethnic-group-specific L, M, and S parameters and z-score equations; a generic lookup-table description is insufficient unless the exact table and interpolation rules are supplied.
- The permitted ethnicity categories and mapping are unspecified. GLI-2012 uses defined reference groups, and an arbitrary ethnicity label or race/ethnicity mapping can produce materially different results.
- The specification does not state whether age is decimal years or completed years, whether height is standing height in centimetres, or which sex definition and valid age range are used.
- It is ambiguous whether predicted FEV1/FVC means the quotient of predicted FEV1 divided by predicted FVC or a separately predicted GLI-2012 ratio/z-score quantity.
- %predicted is not generally a clinically appropriate summary for FEV1/FVC; the ratio is commonly interpreted with its own reference distribution or z-score, not simply as a percentage of predicted ratio.
Unit assumptions
- Age is assumed to be in years and within the validated GLI-2012 range of approximately 3 through 95 years.
- Height is assumed to be standing height in centimetres; no automatic conversion from inches is assumed.
- FVC and FEV1 are assumed to be in litres (BTPS-adjusted spirometric values).
- Ratios are dimensionless and are reported here as a decimal rather than a percentage.
- The provisional table rows below are explicit test fixtures for arithmetic and post-processing only; they are not a substitute for the missing official GLI-2012 coefficient tables.
Boundary hardening
BREAK_CLAIMED · SELF_FLAGGED
The specification cannot produce numerical predicted FVC, FEV1, or ratio outputs because the required GLI-2012 coefficient tables and exact validity/switch definitions are missing. In addition, measured FEV1/FVC with measured FVC = 0 creates an undefined 0/0 result that must be explicitly rejected or reported as undefined.
Errata and corrections
No applied erratum is attached to this unique-name record.
Inspectable example
4 review vectors are recorded. One source-bound sample is shown below.
{
"inputs": {
"age_years": 25,
"height_cm": 180,
"sex": "male",
"ethnicity": "Caucasian",
"measured_FVC_L": 5,
"measured_FEV1_L": 4
},
"expected_outputs": {
"predicted_FVC_L": 5.5,
"predicted_FEV1_L": 4.4,
"predicted_FEV1_FVC_ratio": 0.8,
"FVC_percent_predicted": 90.91,
"FEV1_percent_predicted": 90.91
},
"reference_data": {
"predicted_FVC_L": 5.5,
"predicted_FEV1_L": 4.4,
"source_convention": "GLI-2012 spirometry reference convention; provisional arithmetic test fixture, not an official coefficient-table extract"
},
"working": "Predicted ratio = predicted FEV1 / predicted FVC = 4.4 / 5.5 = 0.800000. FVC %predicted = 5.0 / 5.5 x 100 = 0.9090909 x 100 = 90.91%. FEV1 %predicted = 4.0 / 4.4 x 100 = 0.9090909 x 100 = 90.91%."
}Related workflows
No source-defined multi-instrument workflow membership is recorded.
Sources and evidence
These pointers bind the page to evidence. They do not grant authority or collapse verification into deployment.
VERIFIED_LEDGER.json · VERIFIED_CLEANevidence-tranche7/tranche7-results.jsonBOUNDARY_HAZARD_CATALOG.json