Malus's Law Polarization Calculator

The current ledger marks this instrument verified clean within the source-bound verification corpus.

Status: VERIFIED_CLEANLifecycle: verified-clean

Inspectable records

Ledger state

The current ledger marks this instrument verified clean within the source-bound verification corpus.

Area
Physics — Kinematics/Projectiles/Orbits, Forces/Energy/Momentum, Rotational Dynamics, Gravitation, Oscillations/Waves, Optics, E&M Fields, Relativity, Quantum, Statistical Thermo
Tranche
tranche-5
Evidence ID
t5-156
Ledger rows
1

No ledger note is attached.

Review findings

The single-polarizer formula is standard under its stated physical assumptions. Verdict is NEEDS_REVIEW because the specification simultaneously claims single- and two-polarizer operation without defining the required stack formula or polarization state, and it omits an explicit angle convention and percent-transmission formula.

Formula and scope findings

  • I=I0 cos²θ is correct for fully linearly polarized incident light when θ is the angle between the incident polarization direction and the transmission axis of one ideal polarizer.
  • The stated single-or-two-polarizer input is ambiguous: a two-polarizer stack requires the relative angle between polarizers and a defined initial polarization state. For an initially polarized beam, sequential transmission is I=I0 cos²(θ1) cos²(θ2−θ1); for unpolarized light, the first ideal polarizer transmits I0/2.
  • The percent-transmission output formula is not explicitly stated; it should be 100×I/I0 when I0 is nonzero and the percentage is referenced to the incident intensity.
  • The honest label should explicitly state that the formula does not apply directly to unpolarized incident light unless the first-polarizer I0/2 factor is included.

Unit assumptions

  • I0 and transmitted intensity must use the same intensity units; the test vectors use W/m².
  • θ is dimensionless inside the trigonometric function and must be explicitly interpreted as either degrees or radians. The specification does not select one.
  • Percent transmission is relative to the supplied incident intensity I0, not relative to an unpolarized-beam convention or a lossless maximum after another polarizer.

Boundary hardening

BREAK_CLAIMED · SELF_FLAGGED

The angle unit is unspecified. The input value 60 yields 25% transmission when interpreted as degrees but 90.70904852632809% when interpreted as radians, so the calculator can return a materially wrong result unless the unit convention is explicit or enforced.

Errata and corrections

No applied erratum is attached to this unique-name record.

Inspectable example

4 review vectors are recorded. One source-bound sample is shown below.

{
  "inputs": {
    "I0_W_per_m2": 100,
    "theta": 0,
    "angle_unit": "degrees"
  },
  "expected_outputs": {
    "transmitted_intensity_W_per_m2": 100,
    "percent_transmission": 100
  },
  "working": "cos(0°)=1; cos²(0°)=1²=1; I=100×1=100 W/m²; percent=100×100/100=100%."
}