Page actions
instrument qualification / verified-with-binding-errata
NTU-Effectiveness Heat Exchanger Calculator qualification
Verified with errata that must be applied at binding time.
Ledger verdict
Verified with errata that must be applied at binding time.
- Status
- VERIFIED_WITH_ERRATA
- Tranche
- tranche-4
- Review vectors
- 4
- Ledger rows
- 1
Applied errata
[
{
"vector": 1,
"field": "q_W / T_hot_out / T_cold_out",
"wrong": "q 132,891.81, Tho 116.42, Tco 59.74",
"correct": "q 265,783.63, Tho 52.83, Tco 99.48",
"cause": "q exactly halved; her epsilon 0.7948 is correct and outlets inherit the halving"
}
]Adversarial re-test context
The full catalog was re-tested from boundary, convention, and self-check angles in 2,787 requests. Five genuine computational defects were independently verified and corrected. This page reports the current ledger state for this instrument; it does not imply product deployment or interface qualification.
Release gate
Bind every attached correction, replay the affected vectors, enforce boundary validation, and preserve evidence before describing the executable surface as qualified.
Other records
Sources and evidence
These pointers bind the page to evidence. They do not grant authority or collapse verification into deployment.
VERIFIED_LEDGER.jsonSTRESS_TEST_RECEIPT.jsontranche errata record