UA/Ui/Uo · vector 2
UA 14.033, Ui 44.668, Uo 37.224
UA 13.113, Ui 41.740, Uo 34.783
the specified Rfouling=0.005 K/W omitted from her own resistance sum (removal reproduces her numbers exactly)instrument / verified-with-binding-errata
The current ledger marks this instrument verified with errata that must be applied at binding time.
The current ledger marks this instrument verified with errata that must be applied at binding time.
No ledger note is attached.
The written resistance equation has the correct convection and cylindrical-wall terms, but the fouling term and U area basis are insufficiently defined. The honest label should state whether fouling inputs are total K/W or area-specific m²·K/W, identify inside versus outside fouling surfaces, expose whether the result is Ui or Uo, and disclose the required positivity and unit constraints. The TEMA fouling table also requires a defined source, applicability range, and temperature/fluid assumptions.
BREAK_CLAIMED · SELF_FLAGGED
The calculator should reject k=0 because the wall-resistance term divides by zero. The convention probe also exposes a substantial unit and radius-versus-diameter interpretation hazard if geometry metadata are not enforced.
UA/Ui/Uo · vector 2
UA 14.033, Ui 44.668, Uo 37.224
UA 13.113, Ui 41.740, Uo 34.783
the specified Rfouling=0.005 K/W omitted from her own resistance sum (removal reproduces her numbers exactly)4 review vectors are recorded. One source-bound sample is shown below.
{
"inputs": {
"hi": 1000,
"ho": 50,
"k": 16,
"ri": 0.01,
"ro": 0.012,
"L": 1,
"Rfouling": 0,
"units": "hi,ho W/(m²·K); k W/(m·K); dimensions m; Rfouling K/W"
},
"expected_outputs": {
"UA_W_per_K": 3.534,
"Ui_W_per_m2K": 56.241,
"Uo_W_per_m2K": 46.868
},
"working": "Ai=2π(0.01)(1)=0.0628319 m²; Ao=2π(0.012)(1)=0.0753982 m². Ri=1/(1000×0.0628319)=0.0159155 K/W. Rwall=ln(0.012/0.01)/(2π×16×1)=ln(1.2)/100.531=0.0018136 K/W. Ro=1/(50×0.0753982)=0.2652582 K/W. Rtotal=0.0159155+0+0.0018136+0.2652582=0.2829873 K/W. UA=1/0.2829873=3.5337 W/K. Ui=3.5337/0.0628319=56.241 W/(m²·K). Uo=3.5337/0.0753982=46.868 W/(m²·K)."
}These pointers bind the page to evidence. They do not grant authority or collapse verification into deployment.
VERIFIED_LEDGER.json · VERIFIED_WITH_ERRATAevidence-tranche4/tranche4-results.jsonBOUNDARY_HAZARD_CATALOG.json