Titration Curve Plotter mechanism
The inspectable method record for Titration Curve Plotter, kept separate from implementation and qualification.
Model scope
The supplied formulas are directionally standard for a monoprotic weak acid titrated by a strong base, but they do not fully specify the advertised instrument. The exact ambiguity requiring review is the unsupported meaning of 'strong/weak combinations' and the absence of a defined treatment for weak-base/strong-acid and weak/weak titrations. One arithmetic correction is important in the weak-acid and weak-base vectors: the exact initial quadratic result is 0.00133267 M, giving pH 2.87528 for the weak acid and pH 11.1247 for the weak base.
- The piecewise description is incomplete for the claimed strong/weak acid-base combinations: it does not specify separate charge-balance formulas for strong acid/strong base, weak base/strong acid, or weak acid/weak base titrations.
- At equivalence, using Kb of the conjugate is correct for a weak acid titrated by strong base, but a weak base titrated by strong acid requires Ka of the conjugate acid; weak/weak equivalence requires a different equilibrium treatment.
- The statement half-equivalence pH=pKa is valid only for a monoprotic weak acid titrated by a strong base. For a weak base titrated by strong acid, pOH=pKb and pH=pKw-pKb. It is not generally valid for strong/strong or weak/weak systems.
- The pre-equivalence Henderson-Hasselbalch approximation is not valid at the initial zero-titrant point and can be inaccurate when dissociation is not negligible compared with neutralized analyte.
- The specification does not state stoichiometry assumptions such as monoprotic acid/base behavior; equivalence volume and the piecewise equations change for polyprotic systems.
- A full pH curve requires explicit water autoionization and charge-balance handling near neutrality and at very low concentrations; the listed formulas do not define those cases.
Units and conventions
- All concentrations are mol/L (M), all solution volumes are converted to liters before mole calculations, and titrant/analyte concentrations are analytical concentrations.
- Calculations assume 25 degrees C, with Kw=1.00e-14, pH=-log10[H+], and pOH=-log10[OH-].
- Solutions are treated as ideal: activities are approximated by concentrations and volume additivity is assumed.
- The test vectors use monoprotic acids/bases and 1:1 neutralization stoichiometry.
- Strong acid/base pH values assume complete dissociation; weak-species values use the stated Ka or Kb.
Inspectable vector
One of 4 source-bound review vectors:
{
"inputs": {
"analyte": {
"type": "strong_acid",
"formula": "HCl",
"concentration_M": 0.1,
"volume_mL": 25
},
"titrant": {
"type": "strong_base",
"formula": "NaOH",
"concentration_M": 0.1
},
"sampled_volumes_mL": [
0,
12.5,
25,
30
]
},
"expected_outputs": {
"curve_points": [
{
"volume_mL": 0,
"pH": 1
},
{
"volume_mL": 12.5,
"pH": 1.477121
},
{
"volume_mL": 25,
"pH": 7
},
{
"volume_mL": 30,
"pH": 11.958607
}
],
"equivalence_volume_mL": 25,
"half_equivalence_volume_mL": 12.5,
"half_equivalence_pH": 1.477121,
"key_features": {
"equivalence_point": "pH 7.000000 under the 25 C ideal strong/strong assumption",
"half_equivalence_note": "pH is not pKa; the analyte is a strong acid"
}
},
"working": "Initial acid moles = 0.100 mol/L * 0.0250 L = 0.002500 mol. Equivalence volume = 0.002500 mol / 0.100 mol/L = 0.0250 L = 25.0 mL. At 0 mL: [H+]=0.100, so pH=-log10(0.100)=1.000000. At 12.5 mL: OH- moles=0.100*0.0125=0.001250 mol; remaining H+ moles=0.002500-0.001250=0.001250 mol; total volume=0.0375 L; [H+]=0.001250/0.0375=0.0333333; pH=-log10(0.0333333)=1.477121. At 25.0 mL, strong acid and strong base exactly neutralize, so pH=7.000000. At 30.0 mL: excess OH- moles=0.100*0.0300-0.002500=0.000500 mol; total volume=0.0550 L; [OH-]=0.000500/0.0550=0.00909091; pOH=-log10(0.00909091)=2.041393; pH=14.000000-2.041393=11.958607."
}Failure boundary
BREAK_CLAIMED · SELF_FLAGGED
The zero-concentration titrant case creates a genuine division-by-zero in equivalence-volume calculation and must be rejected. The zero-volume boundary also exposes a likely log10(0) failure if the pre-equivalence Henderson-Hasselbalch formula is applied at the initial point. Volume-direction conventions require explicit handling.
Other records
Sources and evidence
These pointers bind the page to evidence. They do not grant authority or collapse verification into deployment.
VERIFIED_LEDGER.jsonevidence-tranche6/tranche6-results.jsonBOUNDARY_HAZARD_CATALOG.json