Water-Cement Ratio ↔ Strength Estimator implementation
A source-bound implementation contract for Water-Cement Ratio ↔ Strength Estimator; deployment and executable qualification remain separate.
Binding contract
This record describes what an executable surface must bind and validate. It does not claim that a public calculator, package, or production route is deployed.
- Record owner
- Guth Instruments
- Lifecycle
- verified-clean
- Evidence ID
- t7-085
- Effect
- Computation or source lookup only
Input and validation requirements
The specification does not provide the actual ACI table, table version, air-entrainment basis, interpolation rule, or valid input range. Consequently, boundary results and inverse results are not uniquely determined. An extreme target such as 1,000,000,000,000 psi must be rejected; returning an extrapolated w/c value would be a failure.
Required corrections
No binding erratum is attached to this unique-name record. Implementers must still preserve the declared units, domain, and failure behavior.
Inspectable interface fixture
The sample below is evidence for interface and validation tests, not a production implementation.
{
"inputs": {
"mode": "strength_from_wc",
"wc_ratio": 0.58
},
"expected_outputs": {
"estimated_fc_psi": 3000,
"estimated_fc_mpa": 20.6843
},
"reference_data": {
"rows": [
{
"fc_psi": 2500,
"max_wc_ratio": 0.62
},
{
"fc_psi": 3000,
"max_wc_ratio": 0.58
}
],
"source_convention": "ACI 211.1-91 (reapproved 2009), Table 6.3.4(a), non-air-entrained concrete; US customary textbook table values"
},
"working": "Exact table lookup: w/c = 0.58 corresponds to f'c = 3000 psi. Convert units: 3000 psi × 0.006894757293 MPa/psi = 20.684271879 MPa ≈ 20.6843 MPa."