Page actions
instrument mechanism / verified-clean
Water-Cement Ratio ↔ Strength Estimator mechanism
The inspectable method record for Water-Cement Ratio ↔ Strength Estimator, kept separate from implementation and qualification.
Model scope
The supplied honest label is directionally appropriate but incomplete. The instrument should identify the exact ACI edition/table, air-content condition, strength units, interpolation policy, and whether it reports an approximate table-associated strength or a maximum allowable w/c. Without those specifications and the actual table data, the implementation cannot receive an unconditional PASS.
- Abrams' law is named but no explicit equation or calibrated constants are supplied, so that method cannot be independently verified.
- The cited ACI lookup table is an allowable maximum water-cement ratio table for mixture proportioning, not a universal strength-prediction equation; treating its inverse as the required w/c ratio is technically misleading.
- ACI table values depend on the selected table edition, air-entrainment condition, and mixture assumptions. The spec does not identify these choices.
- Linear interpolation between discrete ACI table rows is not explicitly authorized by ACI and should be labeled as an approximation if implemented.
- A target strength alone does not uniquely determine a required w/c ratio because strength also depends on cement type, aggregate, curing, age, air content, admixtures, and testing procedure.
Units and conventions
- w/c is a dimensionless mass ratio: mass of water divided by mass of cementitious material.
- The worked lookup convention is ACI 211.1-91, Table 6.3.4(a), non-air-entrained concrete, with compressive strength in psi and 28-day test age.
- For SI display, 1 psi = 0.006894757293 MPa.
- The ACI entries are treated as maximum w/c ratios associated with nominal 28-day compressive-strength classes, not guaranteed measured strengths.
- The target-strength input unit must be explicitly selected as psi or MPa; the original spec does not specify one.
Inspectable vector
One of 4 source-bound review vectors:
{
"inputs": {
"mode": "strength_from_wc",
"wc_ratio": 0.58
},
"expected_outputs": {
"estimated_fc_psi": 3000,
"estimated_fc_mpa": 20.6843
},
"reference_data": {
"rows": [
{
"fc_psi": 2500,
"max_wc_ratio": 0.62
},
{
"fc_psi": 3000,
"max_wc_ratio": 0.58
}
],
"source_convention": "ACI 211.1-91 (reapproved 2009), Table 6.3.4(a), non-air-entrained concrete; US customary textbook table values"
},
"working": "Exact table lookup: w/c = 0.58 corresponds to f'c = 3000 psi. Convert units: 3000 psi × 0.006894757293 MPa/psi = 20.684271879 MPa ≈ 20.6843 MPa."
}Failure boundary
BREAK_CLAIMED · SELF_FLAGGED
The specification does not provide the actual ACI table, table version, air-entrainment basis, interpolation rule, or valid input range. Consequently, boundary results and inverse results are not uniquely determined. An extreme target such as 1,000,000,000,000 psi must be rejected; returning an extrapolated w/c value would be a failure.
Other records
Sources and evidence
These pointers bind the page to evidence. They do not grant authority or collapse verification into deployment.
VERIFIED_LEDGER.jsonevidence-tranche7/tranche7-results.jsonBOUNDARY_HAZARD_CATALOG.json