Page actions
instrument / verified-clean
EMC/EMI Near-Field Distance & Wavelength Calculator
The current ledger marks this instrument verified clean within the source-bound verification corpus.
Inspectable records
Ledger state
The current ledger marks this instrument verified clean within the source-bound verification corpus.
- Area
- Electrical & Electronics Engineering — Circuits, Power Systems, Electronics Lab
- Tranche
- tranche-5
- Evidence ID
- t5-061
- Ledger rows
- 1
No ledger note is attached.
Review findings
The wavelength formula is standard under SI units. The distance formulas are conditional engineering rules of thumb, and the honest-label warning is appropriate, but the product needs explicit SI input units, D definition, domain constraints, and unambiguous output labels before release.
Formula and scope findings
- The formula λ/2π is a rule-of-thumb scale associated with reactive near-field behavior for some source types; labeling it a general far-field boundary is ambiguous and is not universally valid.
- The Fraunhofer distance 2D²/λ is a standard rule of thumb for the far-field boundary when D is the maximum physical aperture or structure dimension, but its applicability and numerical factor depend on geometry and allowable phase error.
- The specification does not define whether the two distances are separate outputs, whether one should be selected, or whether the larger distance should be treated as the conservative boundary.
- The specification does not state whether D is the maximum overall dimension, aperture diameter, cable length, or another characteristic dimension.
Unit assumptions
- Frequency must be supplied in hertz (Hz).
- Antenna or structure size D must be supplied in metres (m).
- Wavelength is computed in metres using c = 299792458 m/s.
- The λ/2π distance and 2D²/λ distance are approximate rule-of-thumb values, not geometry-independent EMC limits.
- D must be a nonnegative physical length; the Fraunhofer result is unavailable when D is omitted.
Boundary hardening
BREAK_CLAIMED · SELF_FLAGGED
The zero-frequency vector exposes an undefined division-by-zero case that must be rejected. The unit probe also exposes a severe convention hazard: ignoring the D unit changes the Fraunhofer result by four orders of magnitude.
Errata and corrections
No applied erratum is attached to this unique-name record.
Inspectable example
4 review vectors are recorded. One source-bound sample is shown below.
{
"inputs": {
"frequency_hz": 100000000,
"D_m": 0.3
},
"expected_outputs": {
"wavelength_m": 2.99792458,
"reactive_scale_m": 0.477134516,
"fraunhofer_boundary_m": 0.060041537
},
"working": "λ = c/f = 299792458 / 100000000 = 2.99792458 m. Reactive scale = λ/(2π) = 2.99792458 / 6.283185307 = 0.477134516 m. Fraunhofer boundary = 2D²/λ = 2(0.3²)/2.99792458 = 2(0.09)/2.99792458 = 0.18/2.99792458 = 0.060041537 m."
}Related workflows
No source-defined multi-instrument workflow membership is recorded.
Sources and evidence
These pointers bind the page to evidence. They do not grant authority or collapse verification into deployment.
VERIFIED_LEDGER.json · VERIFIED_CLEANevidence-tranche5/tranche5-results.jsonBOUNDARY_HAZARD_CATALOG.json