Solar Charge Controller Sizing (PWM/MPPT)
The current ledger marks this instrument verified clean within the source-bound verification corpus.
Inspectable records
Ledger state
The current ledger marks this instrument verified clean within the source-bound verification corpus.
- Area
- Electrical & Electronics Engineering — Circuits, Power Systems, Electronics Lab
- Tranche
- tranche-4
- Evidence ID
- t4-162
- Ledger rows
- 1
No ledger note is attached.
Review findings
The existing honest label is appropriate but should explicitly state that this is not a complete MPPT-window or controller-capacity determination. To pass, define series/parallel aggregation, require cold-corrected Voc from module datasheet temperature coefficients, check both MPPT voltage limits using array Vmp and temperature conditions, and define whether current sizing is PV-input current or regulated battery-output current.
Formula and scope findings
- Icontroller ≥ Isc × 1.25 is a valid NEC-style minimum-current estimate only if Isc is the total array short-circuit current in amperes and the controller rating being checked is the applicable current rating. It does not by itself verify charge-controller output-current sizing from array power and battery voltage.
- Voc_string < controller max Vin checks only the upper voltage limit. It is not a complete MPPT input-voltage-window check because the controller's minimum MPPT voltage and the array's operating Vmp are missing.
- The formula requires Voc_string at the coldest expected temperature, but no cold-temperature correction formula or required datasheet coefficient is provided. A nominal or STC Voc is insufficient for the maximum-voltage check.
- The specification does not define how Isc and Voc are aggregated for series and parallel strings. Isc normally adds across parallel strings, while Voc adds across series-connected modules.
- The strict less-than comparison is conservative at the controller maximum-voltage boundary, but the specification should explicitly state whether manufacturer-required voltage margin is also required.
Unit assumptions
- Isc is the total array short-circuit current, expressed in amperes.
- Voc_string and controller max Vin use the same voltage unit, volts, and Voc_string is the cold-corrected maximum open-circuit voltage of the complete series string.
- The 1.25 factor is dimensionless.
- The controller current rating is assumed to be compared directly with the calculated 1.25 × Isc value; actual controller output-current sizing may additionally require array power, battery voltage, and controller efficiency or manufacturer limits.
- A complete MPPT-window check would require controller minimum and maximum MPPT voltages plus array Vmp under relevant temperature conditions.
Boundary hardening
BREAK_CLAIMED · SELF_FLAGGED
An extreme but numerically valid Isc input produces Infinity in JavaScript arithmetic, and a negative signed Isc can produce an invalid negative required rating unless the instrument explicitly applies a magnitude convention. Exact voltage equality also correctly fails because the specified comparison is strict.
Errata and corrections
No applied erratum is attached to this unique-name record.
Inspectable example
4 review vectors are recorded. One source-bound sample is shown below.
{
"inputs": {
"array_Isc_A": 10.8,
"cold_corrected_string_Voc_V": 41.2,
"controller_max_input_voltage_V": 60
},
"expected_outputs": {
"required_controller_current_A": 13.5,
"maximum_voltage_check": "PASS"
},
"working": "Required current = Isc × 1.25 = 10.8 A × 1.25 = 10.8 A + (10.8 A × 0.25) = 10.8 A + 2.7 A = 13.5 A. Voltage check: 41.2 V < 60 V, so PASS."
}Related workflows
Sources and evidence
These pointers bind the page to evidence. They do not grant authority or collapse verification into deployment.
VERIFIED_LEDGER.json · VERIFIED_CLEANevidence-tranche4/tranche4-results.jsonBOUNDARY_HAZARD_CATALOG.json